Literature DB >> 28256425

Comparison of 99mTc-MDP SPECT qualitative vs quantitative results in patients with suspected condylar hyperplasia.

D F López Buitrago1, J Ruiz Botero2, C M Corral3, A R Carmona4, A Sabogal2.   

Abstract

OBJECTIVE: To compare qualitative vs quantitative results of Single Photon Emission Computerised Tomography (SPECT), calculated from percentage of 99mTc-MDP (methylene diphosphonate) uptake, in condyles of patients with a presumptive clinical diagnosis of condylar hyperplasia. MATERIALS AND
METHOD: A retrospective, descriptive study was conducted on the 99mTc-MDP SPECT bone scintigraphy reports from 51 patients, with clinical impression of facial asymmetry related to condylar hyperplasia referred by their specialist in orthodontics or maxillofacial surgery, to a nuclear medicine department in order to take this type of test. Quantitative data from 99mTc-MDP condylar uptake of each were obtained and compared with qualitative image interpretation reported by a nuclear medicine expert.
RESULTS: The concordances between the 51 qualitative and quantitative reports results was established. The total sample included 32 women (63%) and 19 men (37%). The patient age range was 13-45 years (21±8 years). According to qualitative reports, 19 patients were positive for right side condylar hyperplasia, 12 for left side condylar hyperplasia, with 8 bilateral, and 12 negative. The quantitative reports diagnosed 16 positives for right side condylar hyperplasia, 10 for left side condylar hyperplasia, and 25 negatives.
CONCLUSIONS: Nuclear medicine images are an important diagnostic tool, but the qualitative interpretation of the images is not as reliable as the quantitative calculation. The agreement between the two types of report is low (39.2%, Kappa=0.13; P>.2). The main limitation of quantitative reports is that they do not register bilateral condylar hyperplasia cases.
Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

Entities:  

Keywords:  Asimetría facial; Bone Scintigraphy; Condylar hyperplasia; Facial asymmetry; Gammagrafía ósea; Hiperplasia condilar; Single Photon Emission Computerised Tomography; Tomografía computarizada de emisión por fotón único

Mesh:

Substances:

Year:  2017        PMID: 28256425     DOI: 10.1016/j.remn.2017.01.003

Source DB:  PubMed          Journal:  Rev Esp Med Nucl Imagen Mol        ISSN: 2253-654X            Impact factor:   1.359


  2 in total

Review 1.  Does quantification have a role to play in the future of bone SPECT?

Authors:  James C Ross; Dijana Vilić; Tom Sanderson; Stefan Vöö; John Dickson
Journal:  Eur J Hybrid Imaging       Date:  2019-05-03

2.  SPECT/CT Correlation in the Diagnosis of Unilateral Condilar Hyperplasia.

Authors:  Diego Fernando López; Valentina Ríos Borrás; Juan Manuel Muñoz; Rodrigo Cardenas-Perilla; Luis Eduardo Almeida
Journal:  Diagnostics (Basel)       Date:  2021-03-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.