Literature DB >> 28255679

Computational Parametric Studies Investigating the Global Hemodynamic Effects of Applied Apical Torsion for Cardiac Assist.

Elaine Soohoo1, Lewis K Waldman2, Dennis R Trumble3.   

Abstract

Healthy hearts have an inherent twisting motion that is caused by large changes in muscle fiber orientation across the myocardial wall and is believed to help lower wall stress and increase cardiac output. It was demonstrated that applied apical torsion (AAT) of the heart could potentially treat congestive heart failure (CHF) by improving hemodynamic function. We report the results of parametric computational experiments where the effects of using a torsional ventricular assist device (tVAD) to treat CHF were examined using a patient-specific bi-ventricular computational model. We examined the effects on global hemodynamics as the device coverage area (CA) and applied rotation angle (ARA) were varied to determine ideal tVAD design parameters. When compared to a baseline, pretreatment CHF model, increases in ARA resulted in moderate to substantial increases in ejection fraction (EF), peak systolic pressures (PSP) and stroke work (SW) with concomitant decreases in end-systolic volumes (ESV). Increases in device CA resulted in increased hemodynamic function. The simulation representing the most aggressive level of cardiac assist yielded significant increases in left ventricular EF and SW, 49 and 72% respectively. Results with this more realistic computational model reinforce previous studies that have demonstrated the potential of AAT for cardiac assist.

Entities:  

Keywords:  Computational modeling; Congestive heart failure; Ventricular assist device

Mesh:

Year:  2017        PMID: 28255679      PMCID: PMC5737712          DOI: 10.1007/s10439-017-1812-x

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  19 in total

1.  Aging, habitual exercise, and dynamic arterial compliance.

Authors:  H Tanaka; F A Dinenno; K D Monahan; C M Clevenger; C A DeSouza; D R Seals
Journal:  Circulation       Date:  2000-09-12       Impact factor: 29.690

2.  Cardiac assist with a twist: apical torsion as a means to improve failing heart function.

Authors:  Dennnis R Trumble; Walter E McGregor; Roy C P Kerckhoffs; Lewis K Waldman
Journal:  J Biomech Eng       Date:  2011-10       Impact factor: 2.097

3.  Coupling of a 3D finite element model of cardiac ventricular mechanics to lumped systems models of the systemic and pulmonic circulation.

Authors:  Roy C P Kerckhoffs; Maxwell L Neal; Quan Gu; James B Bassingthwaighte; Jeff H Omens; Andrew D McCulloch
Journal:  Ann Biomed Eng       Date:  2006-11-08       Impact factor: 3.934

4.  Hemodynamic alterations in acute myocardial infarction. I. Cardiac output, mean arterial pressure, total peripheral resistance, central and total blood volumes, venous pressure and average circulation time.

Authors:  E D FREIS; H W SCHNAPER; R L JOHNSON; G E SCHREINER
Journal:  J Clin Invest       Date:  1952-02       Impact factor: 14.808

5.  Effects of exercise on aortic input impedance and pressure wave forms in normal humans.

Authors:  J P Murgo; N Westerhof; J P Giolma; S A Altobelli
Journal:  Circ Res       Date:  1981-03       Impact factor: 17.367

6.  Aortic compliance in human hypertension.

Authors:  Z R Liu; C T Ting; S X Zhu; F C Yin
Journal:  Hypertension       Date:  1989-08       Impact factor: 10.190

7.  Relation between number of cardiovascular risk factors/events and noninvasive Doppler ultrasound assessments of aortic compliance.

Authors:  E D Lehmann; K D Hopkins; A Rawesh; R C Joseph; K Kongola; S W Coppack; R G Gosling
Journal:  Hypertension       Date:  1998-09       Impact factor: 10.190

8.  Estimation of arterial stiffness, compliance, and distensibility from M-mode ultrasound measurements of the common carotid artery.

Authors:  G Gamble; J Zorn; G Sanders; S MacMahon; N Sharpe
Journal:  Stroke       Date:  1994-01       Impact factor: 7.914

9.  Vascular hemodynamic impedance in congestive heart failure.

Authors:  S M Finkelstein; J N Cohn; V R Collins; P F Carlyle; W J Shelley
Journal:  Am J Cardiol       Date:  1985-02-01       Impact factor: 2.778

10.  Patient-Specific Models of Cardiac Biomechanics.

Authors:  Adarsh Krishnamurthy; Christopher T Villongco; Joyce Chuang; Lawrence R Frank; Vishal Nigam; Ernest Belezzuoli; Paul Stark; David E Krummen; Sanjiv Narayan; Jeffrey H Omens; Andrew D McCulloch; Roy Cp Kerckhoffs
Journal:  J Comput Phys       Date:  2013-07-01       Impact factor: 3.553

View more
  2 in total

1.  Ventricle-specific epicardial pressures as a means to optimize direct cardiac compression for circulatory support: A pilot study.

Authors:  Jooli Han; Matthew Kubala; Edgar Aranda-Michel; Dennis R Trumble
Journal:  PLoS One       Date:  2019-07-05       Impact factor: 3.240

2.  Left ventricular simulation of cardiac compression: Hemodynamics and regional mechanics.

Authors:  Edgar Aranda-Michel; Lewis K Waldman; Dennis R Trumble
Journal:  PLoS One       Date:  2019-10-31       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.