| Literature DB >> 28255404 |
R Sharifi1, A Araghid1, S Ghanem2, A Fatahi3.
Abstract
Introduction: Mineral trioxide aggregate (MTA) has numerous applications in dentistry due to various advantages. However, its long setting time has still remained a problem. The current study was conducted to investigate the effect of temperature (ambient and distilled water temperature) on the setting time of mineral trioxide aggregate (MTA). Materials and methods: This experimental study comprised of two parts. In the first part, MTA and distilled water samples were kept at ambient temperature for 24 hours (before mixing: effect of distilled water temperature on the setting time of MTA and after mixing: effect of distilled water and ambient temperature on the setting time of MTA), and analyzed and divided into three groups: group 1 (4°C), group 2 (37°C) and group 3 (90°C). The mixed samples were placed in the glass cylinders with an internal diameter of 8 mm and a height of 10 mm, and kept at 37°C temperature and 100% humidity. In the second part, the samples were prepared the same as those of the first part and divided into three groups according to the terms of maintenance: group 1 (4°C), group 2 (37°C) and group 3 (75°C). The mixed samples were then put in glass cylinders with an internal diameter of 8 mm and a height of 10 mm and the samples of groups 1, 2 and 3 were kept at 4, 37 and 75 °C, respectively. At the end of each part, the primary and final setting times were measured by Gilmore needle. Data were analyzed by SPSS using Kruskal-Wallis test (p<0.05).Entities:
Keywords: Mineral Trioxide Aggregate (MTA); setting time; temperature
Year: 2015 PMID: 28255404 PMCID: PMC5327716
Source DB: PubMed Journal: J Med Life ISSN: 1844-122X
Number, mean value, and standard deviation for the setting time of MTA at different temperatures in incubator
| Primary needle | Final needle | |||||
| Temperature | Number | Mean | SD | Number | Mean | SD |
| 4°C | 3 | 42 | 3 | 3 | 87 | 3 |
| 37°C | 3 | 27 | 3 | 3 | 47 | 3 |
| 75°C | 3 | 20 | 0 | 3 | 37 | 3 |
Number, mean value, and standard deviation for the setting time of MTA
| Primary needle | Final needle | |||||
| Temperature | Number | Mean | SD | Number | Mean | SD |
| 4°C | 3 | 43 | 3 | 3 | 93 | 3 |
| 37°C | 3 | 25 | 3 | 3 | 75 | 3 |
| 90°C | 3 | 20 | 0 | 3 | 38 | 3 |