Literature DB >> 2824967

Transverse relaxation of solvent protons induced by magnetized spheres: application to ferritin, erythrocytes, and magnetite.

P Gillis1, S H Koenig.   

Abstract

Since 1/T2 of protons of tissue water is generally much greater than 1/T1 at typical imaging fields, small single-ion contrast agents--such as Gd(DTPA), which make comparable incremental contributions and therefore smaller fractional contributions to 1/T2 compared to 1/T1--are not as desirable for contrast-enhancement as agents that could enhance 1/T2 preferentially. In principle, such specialized agents will only be effective at higher fields because the field dependence (dispersion) of 1/T1 is such that it approaches zero at high fields whereas 1/T2 approaches a constant value. The residual 1/T2 is called the "secular" contribution and arises from fluctuations in time--as sensed by the protons of diffusing solvent or tissue water molecules--of the component of the magnetic field parallel to the static applied field. For solutions or suspensions of sufficiently large paramagnetic or ferromagnetic particles (greater than or equal to 250 A diameter), the paramagnetic contributions to the relaxation rates satisfy 1/T2 much greater than 1/T1 at typical imaging fields. We examine the theory of secular relaxation in some detail, particularly as it applies to systems relevant to magnetic resonance imaging, and then analyze the data for solutions, suspensions, or tissue containing ferritin, erythrocytes, agar-bound magnetite particles, and liver with low-density composite polymer-coated magnetite. In most cases we can explain the relaxation data, often quantitatively, in terms of the theory of relaxation of protons (water molecules) diffusing in the outer sphere environments of magnetized particles. The dipolar field produced by these particles has a strong spatial dependence, and its apparent fluctuations in time as seen by the diffusing protons produce spin transitions that contribute to both 1/T1 and /T2 comparably at low fields; for the larger particles, because of dispersion, the secular term dominates at fields of interest. On the basis of the agreement of theory with data for solutions of small paramagnetic complexes, large magnetite particles, and liver containing low-density polymer-coated magnetite agglomerates, it is argued that the theory is sufficiently reliable so that, e.g., for ferritin--for which 1/T2 is unexpectedly large--the source of its large relaxivity must reside in nonideal chemistry of the ferritin core. For blood, it appears that diffusion through intracellular gradients determines 1/T2.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 2824967     DOI: 10.1002/mrm.1910050404

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  50 in total

1.  Microfabricated high-moment micrometer-sized MRI contrast agents.

Authors:  Gary Zabow; Stephen J Dodd; Erik Shapiro; John Moreland; Alan P Koretsky
Journal:  Magn Reson Med       Date:  2010-10-06       Impact factor: 4.668

Review 2.  Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

Authors:  Christine Rümenapp; Bernhard Gleich; Axel Haase
Journal:  Pharm Res       Date:  2012-03-06       Impact factor: 4.200

3.  Multicore assemblies potentiate magnetic properties of biomagnetic nanoparticles.

Authors:  Tae-Jong Yoon; Hakho Lee; Huilin Shao; Scott A Hilderbrand; Ralph Weissleder
Journal:  Adv Mater       Date:  2011-09-26       Impact factor: 30.849

Review 4.  Recent Developments in Magnetic Diagnostic Systems.

Authors:  Hakho Lee; Tae-Hyun Shin; Jinwoo Cheon; Ralph Weissleder
Journal:  Chem Rev       Date:  2015-08-10       Impact factor: 60.622

Review 5.  MRI contrast agents for functional molecular imaging of brain activity.

Authors:  Alan Jasanoff
Journal:  Curr Opin Neurobiol       Date:  2007-10       Impact factor: 6.627

6.  Magnetic microparticle aggregation for viscosity determination by MR.

Authors:  Rui Hong; Michael J Cima; Ralph Weissleder; Lee Josephson
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

Review 7.  Transverse NMR relaxation in biological tissues.

Authors:  Valerij G Kiselev; Dmitry S Novikov
Journal:  Neuroimage       Date:  2018-06-07       Impact factor: 6.556

8.  Quantifying magnetic nanoparticles in non-steady flow by MRI.

Authors:  Yimin Shen; Yu-Chung N Cheng; Gavin Lawes; Jaladhar Neelavalli; Chandran Sudakar; Ronald Tackett; Hari P Ramnath; E Mark Haacke
Journal:  MAGMA       Date:  2008-08-29       Impact factor: 2.310

9.  Sensitive NMR sensors detect antibodies to influenza.

Authors:  Isaac Koh; Rui Hong; Ralph Weissleder; Lee Josephson
Journal:  Angew Chem Int Ed Engl       Date:  2008       Impact factor: 15.336

10.  Interplay between longitudinal and transverse contrasts in Fe3O4 nanoplates with (111) exposed surfaces.

Authors:  Zijian Zhou; Zhenghuan Zhao; Hui Zhang; Zhenyu Wang; Xiaoyuan Chen; Ruifang Wang; Zhong Chen; Jinhao Gao
Journal:  ACS Nano       Date:  2014-08-26       Impact factor: 15.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.