| Literature DB >> 28247117 |
Femke M A P Claessen1, Michel P J van den Bekerom2, C Niek van Dijk3, J Carel Goslings4, Gino M M J Kerkhoffs5, Job N Doornberg6.
Abstract
BACKGROUND: In some settings, specific techniques for open reduction and internal fixation are preferred based on the eminence of a surgeon or professional organization. An emphasis on technical aspects of surgery that are not proved superior and vary substantially from surgeon to surgeon can be confusing for trainees. This study applied a numerical grading of the technical aspects of tension band wire (TBW) fixation for olecranon fracture; assessed the interobserver agreement of each criterion; and measured the correlation of the technical grading and objective and subjective long-term outcomes.Entities:
Keywords: Disability; Elbow trauma; Olecranon fracture; Technique pain; Tension band
Mesh:
Year: 2017 PMID: 28247117 PMCID: PMC5585090 DOI: 10.1007/s10195-017-0450-2
Source DB: PubMed Journal: J Orthop Traumatol ISSN: 1590-9921
Observer demographics (n = 40)
| Demographic | Number (%) |
|---|---|
| Sex | |
| Male | 38 (95) |
| Female | 2 (5) |
| Years in practice | |
| <3 | 14 (35) |
| 4–6 | 11 (27.5) |
| 7–10 | 8 (20) |
| 11–20 | 6 (15) |
| 21–30 | 1 (2.5) |
| Involvement in resident training | |
| Yes | 21 (52.5) |
| No | 19 (47.5) |
| Number of olecranon fractures treated per year | |
| <5 | 23 (57.5) |
| 6–10 | 13 (32.5) |
| 11–20 | 4 (10) |
| >20 | 0 (0) |
Schneider criteria
| Schneider criteria |
| Oversized Kirschner wires in terms of length |
| Loose figure-of-eight configuration (i.e. the wire cerclage not ‘flush’ to the bone) |
| Incorrect reduction (i.e. congruent joint articular surface) |
| Perforation of the joint surface |
| Non-parallel Kirschner wires (with reference to the other Kirschner wire) on anterior–posterior view |
| Kirschner wires extending radially outwards |
| Proximal ends of the Kirschner wires not bent 180 degrees back into the cortical bone of the olecranon |
| Two intramedullary Kirschner wires |
| Single wire knot |
| Prominent wire knot(s) (i.e. twisted ends not sufficiently bent back into direct contact with the bone) |
Fig. 1Antero–posterior and lateral radiograph of a simple olecranon fracture. It can be conflicting if twisted ends of the wire knot were sufficiently bent back into direct contact with the bone
Fig. 2Antero–posterior and lateral radiograph of a simple olecranon fracture. It can be conflicting if the Kirschner wires were oversized in term of length and if twisted ends of the wire knot were sufficiently bent back into direct contact with the bone
Average number of flaws per case
| Case | Average number deviations | % of observers that would perform the surgery differently | % of observers that recommend revision | F–E Arc | E/F | Mayo elbow performance index | Arthrosis score | DASH score |
|---|---|---|---|---|---|---|---|---|
| 21 | 4.7 | 97.5 | 70 | 135 | 5–140 | 100 | 0 | 1 |
| 24 | 4.1 | 87.5 | 60 | 140 | 0–140 | 100 | 0 | 0 |
| 4 | 3.7 | 85 | 35 | 135 | 5–140 | 100 | 1 | 14 |
| 20 | 3.7 | 95 | 20 | 140 | 0–140 | 100 | 0 | 1 |
| 1 | 3.5 | 90 | 0 | 145 | 0–145 | 100 | 0 | 1 |
| 5 | 3.5 | 70 | 8 | 95 | 15–110 | 65 | 0 | 37 |
| 9 | 3.4 | 85 | 2.5 | 145 | 5–150 | 100 | 0 | 17 |
| 22 | 3.4 | 87.5 | 57.5 | 150 | 0–150 | 100 | 0 | 2 |
| 16 | 3.3 | 80 | 5 | 135 | 10–145 | 100 | 1 | 0 |
| 26 | 3.3 | 90 | 22.5 | 100 | 35–135 | 95 | 1 | 3 |
| 2 | 3.2 | 83 | 23 | 145 | 10–155 | 100 | 0 | 65 |
| 3 | 3.1 | 60 | 10 | 155 | 0–155 | 100 | 0 | 1 |
| 18 | 3.2 | 82.5 | 20 | 135 | 5–140 | 100 | 0 | 13 |
| 12 | 3.0 | 87.5 | 2.5 | 155 | 0–155 | 100 | 0 | 0 |
| 17 | 2.9 | 85 | 0 | 140 | 0–140 | 100 | 0 | 25 |
| 19 | 2.9 | 67.5 | 40 | 130 | 0–130 | 85 | 0 | 17 |
| 11 | 2.8 | 92.5 | 8 | 130 | 0–130 | 100 | 0 | 1 |
| 13 | 2.7 | 87.5 | 5 | 150 | 5–155 | 100 | 0 | 0 |
| 6 | 2.6 | 85 | 15 | 155 | 5–150 | 100 | 0 | 0 |
| 23 | 2.6 | 95 | 27.5 | 160 | 10–150 | 100 | 0 | 0 |
| 14 | 2.4 | 87.5 | 0 | 140 | 0–140 | 100 | 0 | 0 |
| 25 | 2.3 | 82.5 | 5 | 130 | 5–135 | 100 | 0 | 3 |
| 10 | 1.9 | 87.5 | 0 | 140 | 0–140 | 100 | 0 | 1 |
| 15 | 1.9 | 87.5 | 8 | 125 | 5–130 | 100 | 1 | 0 |
| 8 | 1.8 | 22.5 | 8 | 150 | 5–155 | 45 | 0 | 30 |
| 7 | 1.5 | 57.5 | 8 | 150 | –150 | 100 | 0 | 8 |
| Total | 3.0 | 81.5 | 17.7 Average | 139 | 96 | 0.2 | 9 |
F flexion, E extension, DASH disabilities of the arm, shoulder and hand
Interobserver agreement total number of deficiencies
| Criterium | Categorical | Intra class correlation coefficient (CI) |
|---|---|---|
| Total number of deviations per case | Fair agreement | 0.32 (0.21–0.48) |
CI confidence interval