Correction: A Comparison of the Corrected Intraocular Pressure Obtained by the Corvis ST and Reichert 7CR Tonometers in Glaucoma Patients.

.   

Abstract

[This corrects the article DOI: 10.1371/journal.pone.0170206.].

Entities:  

Year:  2017        PMID: 28245278      PMCID: PMC5330536          DOI: 10.1371/journal.pone.0173306

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Due to issues with the typesetting process, there are errors in Table 3. The publisher apologizes for the errors. Please see the correct Table 3 here.
Table 3

The results of univariate and multiple regression analyses: Factors independently associated with the intraocular pressure measurements (β, p, VIF).

Independent variablesIOP measurements
CST-IOPpachyCST-IOPGAT-IOP7CR-IOPg7CR-IOPcc
βpVIFβpVIFβpVIFβpVIFβpVIF
Univariate regression analysis
Gender (female)0.320.2290.550.0450.610.0100.720.0290.350.227
Age (year)-0.020.367-0.020.482-0.020.282-0.020.4540.000.980
Spherical equivalent (diopter)-0.010.9350.000.989-0.060.6650.080.6910.160.365
Average corneal curvature (mm)-2.340.015-2.400.015-1.320.129-1.130.351-0.110.920
Axial length (mm)-0.180.280-0.180.285-0.100.506-0.170.404-0.140.438
Central corneal thickness (μm)0.000.7080.030.0020.020.0250.030.0010.010.529
Stepwise multivariate regression analysis
Gender (female)0.520.0271.00.530.0981.0
Age (year)-0.030.1731.0
Spherical equivalent (diopter)
Average corneal curvature (mm)-2.560.0091.0-2.670.0041.0
Axial length (mm)
Central corneal thickness (μm)0.030.0011.00.010.0711.00.030.0051.0

P values < 0.05 are shown in bold.

VIF, variance inflation factor (VIF > 5.0 indicates a collinearity issue); IOP, intraocular pressure; CST-IOP indicates the IOP using the Corvis ST; CST-IOPpachy, corrected CST-IOP; GAT-IOP, IOP using the Goldmann applanation tonometer; 7CR-IOPg, Goldmann-correlated IOP as measured by the 7CR tonometer; 7CR-IOPcc, corneal-compensated IOP as measured by the 7CR tonometer.

P values < 0.05 are shown in bold. VIF, variance inflation factor (VIF > 5.0 indicates a collinearity issue); IOP, intraocular pressure; CST-IOP indicates the IOP using the Corvis ST; CST-IOPpachy, corrected CST-IOP; GAT-IOP, IOP using the Goldmann applanation tonometer; 7CR-IOPg, Goldmann-correlated IOP as measured by the 7CR tonometer; 7CR-IOPcc, corneal-compensated IOP as measured by the 7CR tonometer.
  1 in total

1.  A Comparison of the Corrected Intraocular Pressure Obtained by the Corvis ST and Reichert 7CR Tonometers in Glaucoma Patients.

Authors:  Yoshitaka Nakao; Yoshiaki Kiuchi; Satoshi Okimoto
Journal:  PLoS One       Date:  2017-01-17       Impact factor: 3.240