Literature DB >> 28243794

Discrete tomography in an in vivo small animal bone study.

Elke Van de Casteele1, Egon Perilli2, Wim Van Aarle3, Karen J Reynolds2, Jan Sijbers3.   

Abstract

This study aimed at assessing the feasibility of a discrete algebraic reconstruction technique (DART) to be used in in vivo small animal bone studies. The advantage of discrete tomography is the possibility to reduce the amount of X-ray projection images, which makes scans faster and implies also a significant reduction of radiation dose, without compromising the reconstruction results. Bone studies are ideal for being performed with discrete tomography, due to the relatively small number of attenuation coefficients contained in the image [namely three: background (air), soft tissue and bone]. In this paper, a validation is made by comparing trabecular bone morphometric parameters calculated from images obtained by using DART and the commonly used standard filtered back-projection (FBP). Female rats were divided into an ovariectomized (OVX) and a sham-operated group. In vivo micro-CT scanning of the tibia was done at baseline and at 2, 4, 8 and 12 weeks after surgery. The cross-section images were reconstructed using first the full set of projection images and afterwards reducing them in number to a quarter and one-sixth (248, 62, 42 projection images, respectively). For both reconstruction methods, similar changes in morphometric parameters were observed over time: bone loss for OVX and bone growth for sham-operated rats, although for DART the actual values were systematically higher (bone volume fraction) or lower (structure model index) compared to FBP, depending on the morphometric parameter. The DART algorithm was, however, more robust when using fewer projection images, where the standard FBP reconstruction was more prone to noise, showing a significantly bigger deviation from the morphometric parameters obtained using all projection images. This study supports the use of DART as a potential alternative method to FBP in X-ray micro-CT animal studies, in particular, when the number of projections has to be drastically minimized, which directly reduces scanning time and dose.

Entities:  

Keywords:  Bone morphological parameters; Discrete tomography; Small animal imaging; X-ray micro-CT

Mesh:

Year:  2017        PMID: 28243794     DOI: 10.1007/s00774-017-0815-x

Source DB:  PubMed          Journal:  J Bone Miner Metab        ISSN: 0914-8779            Impact factor:   2.626


  13 in total

1.  The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffolds.

Authors:  S Van Bael; Y C Chai; S Truscello; M Moesen; G Kerckhofs; H Van Oosterwyck; J-P Kruth; J Schrooten
Journal:  Acta Biomater       Date:  2012-04-07       Impact factor: 8.947

2.  Optimal threshold selection for tomogram segmentation by projection distance minimization.

Authors:  K J Batenburg; J Sijbers
Journal:  IEEE Trans Med Imaging       Date:  2008-12-09       Impact factor: 10.048

3.  3D imaging of nanomaterials by discrete tomography.

Authors:  K J Batenburg; S Bals; J Sijbers; C Kübel; P A Midgley; J C Hernandez; U Kaiser; E R Encina; E A Coronado; G Van Tendeloo
Journal:  Ultramicroscopy       Date:  2009-01-31       Impact factor: 2.689

4.  Quantitative three-dimensional modeling of zeotile through discrete electron tomography.

Authors:  Sara Bals; K Joost Batenburg; Duoduo Liang; Oleg Lebedev; Gustaaf Van Tendeloo; Alexander Aerts; Johan A Martens; Christine E A Kirschhock
Journal:  J Am Chem Soc       Date:  2009-04-08       Impact factor: 15.419

5.  Performance improvements for iterative electron tomography reconstruction using graphics processing units (GPUs).

Authors:  W J Palenstijn; K J Batenburg; J Sijbers
Journal:  J Struct Biol       Date:  2011-08-05       Impact factor: 2.867

6.  DART: a practical reconstruction algorithm for discrete tomography.

Authors:  Kees Joost Batenburg; Jan Sijbers
Journal:  IEEE Trans Image Process       Date:  2011-03-24       Impact factor: 10.856

7.  Fast and flexible X-ray tomography using the ASTRA toolbox.

Authors:  Wim van Aarle; Willem Jan Palenstijn; Jeroen Cant; Eline Janssens; Folkert Bleichrodt; Andrei Dabravolski; Jan De Beenhouwer; K Joost Batenburg; Jan Sijbers
Journal:  Opt Express       Date:  2016-10-31       Impact factor: 3.894

8.  Detecting early bone changes using in vivo micro-CT in ovariectomized, zoledronic acid-treated, and sham-operated rats.

Authors:  E Perilli; V Le; B Ma; P Salmon; K Reynolds; N L Fazzalari
Journal:  Osteoporos Int       Date:  2009-10-07       Impact factor: 4.507

9.  A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants.

Authors:  Hoi Man Wong; Kelvin W K Yeung; Kin On Lam; Vivian Tam; Paul K Chu; Keith D K Luk; Kenneth M C Cheung
Journal:  Biomaterials       Date:  2009-12-29       Impact factor: 12.479

10.  Application of in vivo micro-computed tomography in the temporal characterisation of subchondral bone architecture in a rat model of low-dose monosodium iodoacetate-induced osteoarthritis.

Authors:  Geetha Mohan; Egon Perilli; Julia S Kuliwaba; Julia M Humphries; Ian H Parkinson; Nicola L Fazzalari
Journal:  Arthritis Res Ther       Date:  2011-12-21       Impact factor: 5.156

View more
  1 in total

1.  Iterative and discrete reconstruction in the evaluation of the rabbit model of osteoarthritis.

Authors:  Juuso H Ketola; Sakari S Karhula; Mikko A J Finnilä; Rami K Korhonen; Walter Herzog; Samuli Siltanen; Miika T Nieminen; Simo Saarakkala
Journal:  Sci Rep       Date:  2018-08-13       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.