Literature DB >> 28241117

Supported Microwires for Electroanalysis: Sensitive Amperometric Detection of Reduced Glutathione.

Kamonwad Ngamchuea1, Chuhong Lin1, Christopher Batchelor-McAuley1, Richard G Compton1.   

Abstract

A carbon microfiber (7 μm diameter) is employed herein as an electroanalytical sensor. The fabricated sensor is cheap, is disposable, and requires only 150 μL of samples. The carbon fiber is surface-mounted onto an inert surface to overcome the problems of the fragility of the microwire and the possible interference of convective force due to the nonrigid nature of the wires, as well as to improve the reproducibility in length and the amperometric responses. As the cylindrical electrode is supported on a surface, the diffusion of redox-active species to the electrode is partially blocked by the substrate. A theoretical model is developed to account for this hindered diffusion. The mass-transport regime is altered from "linear" at very short time, where the amperometric responses of the supported microwire closely resemble that of an isolated free-standing cylinder (current ∝ electrode area), to "convergent" at long time where its response now tends toward that of a hemicylinder of equal radius. The model is validated using chronoamperometry and cyclic voltammetry of an ideal outer-sphere redox probe, reversible ferrocene methanol oxidation. The fabricated microwire electrode is further applied to the system of irreversible 2-nitro-5-thiobenzoate oxidation used in the detection of reduced glutathione (GSH). The microwire electrode shows significantly higher ratio of Faradaic to non-Faradaic currents as compared to microdisk, macrodisk or carbon nanotube modified electrodes. Using the fabricated microwire, GSH can be detected with the sensitivity of 0.7 nA μM-1 and the limit of detection of 0.5 μM (3 sB/m).

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28241117     DOI: 10.1021/acs.analchem.7b00372

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Microporous carbon in the selective electro-oxidation of molecular biomarkers: uric acid, ascorbic acid, and dopamine.

Authors:  Tidapa Rattanaumpa; Santi Maensiri; Kamonwad Ngamchuea
Journal:  RSC Adv       Date:  2022-06-27       Impact factor: 4.036

2.  Coupled Optical and Electrochemical Probing of Silver Nanoparticle Destruction in a Reaction Layer.

Authors:  Christopher A Little; Christopher Batchelor-McAuley; Kamonwad Ngamchuea; Chuhong Lin; Neil P Young; Richard G Compton
Journal:  ChemistryOpen       Date:  2018-05-23       Impact factor: 2.911

3.  Effect of Electrode Shape and Flow Conditions on the Electrochemical Detection with Band Microelectrodes.

Authors:  Maher Al Khatib; Marco Bellini; Rebecca Pogni; Andrea Giaccherini; Massimo Innocenti; Francesco Vizza; Alessandro Lavacchi
Journal:  Sensors (Basel)       Date:  2018-09-21       Impact factor: 3.576

  3 in total