Christopher Hoyne1, Marcus Dreosti2, John Shakeshaft3, Siddartha Baxi4.
Abstract
INTRODUCTION: Recent studies have suggested reducing the dose submandibular glands receive when patients undergo head and neck radiotherapy can play a crucial role in preventing xerostomia. However, they are traditionally not spared due to concern that target coverage may be compromised. We investigated the possibility of sparing the contralateral submandibular gland (cSM) by utilising modern planning techniques.Entities:
Keywords: IMRT; VMAT; radiotherapy; submandibular; xerostomia
Mesh:
Year: 2017 PMID: 28240447 PMCID: PMC5454328 DOI: 10.1002/jmrs.203
Source DB: PubMed Journal: J Med Radiat Sci ISSN: 2051-3895
Figure 1Delineated anatomy on sample Axial cross‐section. PTV, planning target volume; RSM, right submandibular gland; LSM, left submandibular gland
Mean results of the 10 patients included in study
| IMRT | VMAT |
| |
|---|---|---|---|
| PTV boost (V95(%)) | 99.2 ± 0.2 | 99.2 ± 0.3 | 0.702 |
| PTV elect (V95(%)) | 99.1 ± 0.1 | 99.1 ± 0.1 | 0.226 |
| Submandibular gland mean dose | |||
| Contralateral (Gy) | 34.7 ± 4.8 | 31.5 ± 5.5 | 0.004 |
| Ipsilateral (Gy) | 59.4 ± 13.0 | 57.8 ± 13.1 | 0.011 |
| CI PTV boost | 1.54 ± 0.2 | 1.41 ± 0.1 | 0.003 |
| MU | 725 | 530 | 3.56E−5
|
V95, The volume of the structure (%) receiving 95% of the prescribed dose; PTV, planned target volume; CI, conformity index; MU, monitor unit; IMRT, intensity modulated radiation therapy; VMAT, volumetric modulated radiation therapy; P‐value, Paired sample t‐test (P < 0.05).
Statistically significant.
Figure 2Typical dose distribution for intensity modulated radiation therapy and VMAT plans aimed at sparing the cSM gland on sample axial cross‐section. The planned target volume (PTV) boost volume is delineated in red, the PTV elect is delineated in blue. The submandibular glands are outlined in pink. The dose to the cSM was reduced to a mean dose of under 39 Gy whilst preserving target coverage. The isodose lines highlight the improved conformity on the VMAT plan, with the yellow 45 Gy and light purple 35 Gy isodose closely following target volume, also lowering the mean dose to the structure. Purple – 73.5 Gy, Red – 70 Gy, Cyan – 66.5 Gy, Light Green – 53.2 Gy, Yellow – 45 Gy, Light Purple – 35 Gy.