| Literature DB >> 28238258 |
Zhuangqiang Gao1,2, Grace G Liu3, Haihang Ye1, Robert Rauschendorfer1, Dianping Tang2, Xiaohu Xia1.
Abstract
Although various colorimetric methods have been actively developed for the detection of Ag+ ions because of their simplicity and reliability, the limits of detection of these methods are confined to the nanomolar (nM) level. Here, we demonstrate a novel strategy for colorimetric Ag+ detection with picomolar (pM) sensitivity. This strategy involves the use of poly(vinylpyrrolidone)- (PVP-) capped Pt nanocubes as artificial peroxidases that can effectively generate a colored signal by catalyzing the oxidation of peroxidase substrates. In the presence of Ag+ ions, the colored signal generated by these Pt cubes is greatly diminished because of the specific and efficient inhibition of Ag+ toward the peroxidase-like activity of the Pt cubes. This colorimetric method can achieve an ultralow detection limit of 80 pM and a wide dynamic range of 10-2-104 nM. To the best of our knowledge, the method presented in this work shows the highest sensitivity for Ag+ detection among all reported colorimetric methods. Moreover, this method also features simplicity and rapidness as it can be conducted at room temperature, in aqueous solution, and requires only ∼6 min.Entities:
Year: 2017 PMID: 28238258 DOI: 10.1021/acs.analchem.6b05026
Source DB: PubMed Journal: Anal Chem ISSN: 0003-2700 Impact factor: 6.986