Literature DB >> 28237187

Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation.

Vincent Richard1, Aurelio Cappozzo2, Raphaël Dumas3.   

Abstract

Estimating joint kinematics from skin-marker trajectories recorded using stereophotogrammetry is complicated by soft tissue artefact (STA), an inexorable source of error. One solution is to use a bone pose estimator based on multi-body kinematics optimisation (MKO) embedding joint constraints to compensate for STA. However, there is some debate over the effectiveness of this method. The present study aimed to quantitatively assess the degree of agreement between reference (i.e., artefact-free) knee joint kinematics and the same kinematics estimated using MKO embedding six different knee joint models. The following motor tasks were assessed: level walking, hopping, cutting, running, sit-to-stand, and step-up. Reference knee kinematics was taken from pin-marker or biplane fluoroscopic data acquired concurrently with skin-marker data, made available by the respective authors. For each motor task, Bland-Altman analysis revealed that the performance of MKO varied according to the joint model used, with a wide discrepancy in results across degrees of freedom (DoFs), models and motor tasks (with a bias between -10.2° and 13.2° and between -10.2mm and 7.2mm, and with a confidence interval up to ±14.8° and ±11.1mm, for rotation and displacement, respectively). It can be concluded that, while MKO might occasionally improve kinematics estimation, as implemented to date it does not represent a reliable solution to the STA issue.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Keywords:  Degree of agreement; Human locomotion; Kinematic constraints; Knee joint; Multi-body kinematics optimisation; Soft tissue artefact

Mesh:

Year:  2017        PMID: 28237187     DOI: 10.1016/j.jbiomech.2017.01.030

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  In vivo static and dynamic lengthening measurements of the posterior cruciate ligament at high knee flexion angles.

Authors:  Caecilia Charbonnier; Victoria B Duthon; Sylvain Chagué; Frank C Kolo; Jacques Ménétrey
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-12-20       Impact factor: 2.924

2.  Description of soft tissue artifacts and related consequences on hindlimb kinematics during canine gait.

Authors:  Cheng-Chung Lin; Shi-Nuan Wang; Ming Lu; Tzu-Yi Chao; Tung-Wu Lu; Ching-Ho Wu
Journal:  PeerJ       Date:  2020-06-26       Impact factor: 2.984

3.  A Simple Algorithm for Assimilating Marker-Based Motion Capture Data During Periodic Human Movement Into Models of Multi-Rigid-Body Systems.

Authors:  Yasuyuki Suzuki; Takuya Inoue; Taishin Nomura
Journal:  Front Bioeng Biotechnol       Date:  2018-10-18

4.  The impact of thigh and shank marker quantity on lower extremity kinematics using a constrained model.

Authors:  Annelise A Slater; Todd J Hullfish; Josh R Baxter
Journal:  BMC Musculoskelet Disord       Date:  2018-11-13       Impact factor: 2.362

  4 in total