K J D A Buijssen1,2,3, J J H Oosterhof1, L Basil4, M Waters4, M A Duits1, H J Busscher2, H C van der Mei2, B F A M van der Laan1. 1. Department of Otorhinolaryngology-Head and Neck Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands. 2. Department of Biomedical Engineering, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands. 3. Department of Otorhinolaryngology, Albert Schweitzer Hospital, Dordrecht, The Netherlands. 4. Principality Medical Ltd., Newport, UK.
Abstract
OBJECTIVES: Evaluation of the influence of a smooth surface moulding technique of silicone rubber indwelling voice prostheses on in vitro biofilm formation and analysis of the clinical in situ lifetime. DESIGN: Biofilm formation on smooth and Groningen ultra low resistance (URL) prostheses was studied in an artificial throat model. The clinical lifetime of smooth voice prostheses was compared to the previous lifetime of URL by counting the number of replacements in a consecutive 6-month period in the same patient. PARTICIPANTS: Eleven laryngectomised patients in follow-up who required frequent replacement of their voice prostheses. SETTINGS: Tertiary University Medical Center. RESULTS: Use of a smoother mould and less viscous silicone rubber yielded a decrease in surface roughness from 46 to 8 nm and was accompanied by a 40% reduction in the prevalence of bacteria and yeast in in vitro formed biofilms. Clinically, the lifetime was significantly (P<.005) increased by a factor of 2.1. CONCLUSIONS: This combined in vitro and clinical study suggests that the choice of material and in particular its surface finishing may be determining factors with respect to the clinical lifetime of silicone rubber implants and devices failing due to biofilm formation.
OBJECTIVES: Evaluation of the influence of a smooth surface moulding technique of silicone rubber indwelling voice prostheses on in vitro biofilm formation and analysis of the clinical in situ lifetime. DESIGN: Biofilm formation on smooth and Groningen ultra low resistance (URL) prostheses was studied in an artificial throat model. The clinical lifetime of smooth voice prostheses was compared to the previous lifetime of URL by counting the number of replacements in a consecutive 6-month period in the same patient. PARTICIPANTS: Eleven laryngectomised patients in follow-up who required frequent replacement of their voice prostheses. SETTINGS: Tertiary University Medical Center. RESULTS: Use of a smoother mould and less viscous silicone rubber yielded a decrease in surface roughness from 46 to 8 nm and was accompanied by a 40% reduction in the prevalence of bacteria and yeast in in vitro formed biofilms. Clinically, the lifetime was significantly (P<.005) increased by a factor of 2.1. CONCLUSIONS: This combined in vitro and clinical study suggests that the choice of material and in particular its surface finishing may be determining factors with respect to the clinical lifetime of silicone rubber implants and devices failing due to biofilm formation.
Authors: Louise Carson; Ruth Merkatz; Elena Martinelli; Peter Boyd; Bruce Variano; Teresa Sallent; Robert Karl Malcolm Journal: Pharmaceutics Date: 2021-05-19 Impact factor: 6.321