Oliver Zettinig1,2, Benjamin Frisch3,4, Salvatore Virga3,4, Marco Esposito3,4, Anna Rienmüller5,6, Bernhard Meyer5, Christoph Hennersperger3,4, Yu-Mi Ryang5, Nassir Navab3,4. 1. Computer Aided Medical Procedures, Technische Universität München, Boltzmannstr. 3, 85748, Garching, Germany. oliver.zettinig@tum.de. 2. Computer Aided Medical Procedures, Johns Hopkins University, 3400 North Charles Street, Baltimore, MD, 21218, USA. oliver.zettinig@tum.de. 3. Computer Aided Medical Procedures, Technische Universität München, Boltzmannstr. 3, 85748, Garching, Germany. 4. Computer Aided Medical Procedures, Johns Hopkins University, 3400 North Charles Street, Baltimore, MD, 21218, USA. 5. Neurochirurgische Klinik und Poliklinik, Technische Universität München, Klinikum rechts der Isar, Ismaninger Str. 22, 81675, München, Germany. 6. Department of Orthopedic Surgery, Medical University Vienna, General Hospital, Vienna, Austria.
Abstract
PURPOSE: We present a fully image-based visual servoing framework for neurosurgical navigation and needle guidance. The proposed servo-control scheme allows for compensation of target anatomy movements, maintaining high navigational accuracy over time, and automatic needle guide alignment for accurate manual insertions. METHOD: Our system comprises a motorized 3D ultrasound (US) transducer mounted on a robotic arm and equipped with a needle guide. It continuously registers US sweeps in real time with a pre-interventional plan based on CT or MR images and annotations. While a visual control law maintains anatomy visibility and alignment of the needle guide, a force controller is employed for acoustic coupling and tissue pressure. We validate the servoing capabilities of our method on a geometric gel phantom and real human anatomy, and the needle targeting accuracy using CT images on a lumbar spine gel phantom under neurosurgery conditions. RESULTS: Despite the varying resolution of the acquired 3D sweeps, we achieved direction-independent positioning errors of [Formula: see text] mm and [Formula: see text], respectively. Our method is capable of compensating movements of around 25 mm/s and works reliably on human anatomy with errors of [Formula: see text] mm. In all four manual insertions by an expert surgeon, a needle could be successfully inserted into the facet joint, with an estimated targeting accuracy of [Formula: see text] mm, superior to the gold standard. CONCLUSION: The experiments demonstrated the feasibility of robotic ultrasound-based navigation and needle guidance for neurosurgical applications such as lumbar spine injections.
PURPOSE: We present a fully image-based visual servoing framework for neurosurgical navigation and needle guidance. The proposed servo-control scheme allows for compensation of target anatomy movements, maintaining high navigational accuracy over time, and automatic needle guide alignment for accurate manual insertions. METHOD: Our system comprises a motorized 3D ultrasound (US) transducer mounted on a robotic arm and equipped with a needle guide. It continuously registers US sweeps in real time with a pre-interventional plan based on CT or MR images and annotations. While a visual control law maintains anatomy visibility and alignment of the needle guide, a force controller is employed for acoustic coupling and tissue pressure. We validate the servoing capabilities of our method on a geometric gel phantom and real human anatomy, and the needle targeting accuracy using CT images on a lumbar spine gel phantom under neurosurgery conditions. RESULTS: Despite the varying resolution of the acquired 3D sweeps, we achieved direction-independent positioning errors of [Formula: see text] mm and [Formula: see text], respectively. Our method is capable of compensating movements of around 25 mm/s and works reliably on human anatomy with errors of [Formula: see text] mm. In all four manual insertions by an expert surgeon, a needle could be successfully inserted into the facet joint, with an estimated targeting accuracy of [Formula: see text] mm, superior to the gold standard. CONCLUSION: The experiments demonstrated the feasibility of robotic ultrasound-based navigation and needle guidance for neurosurgical applications such as lumbar spine injections.
Entities:
Keywords:
3D Ultrasound; Needle insertion; Neurosurgical navigation; Registration-based visual servoing
Authors: Marc Modat; Gerard R Ridgway; Zeike A Taylor; Manja Lehmann; Josephine Barnes; David J Hawkes; Nick C Fox; Sébastien Ourselin Journal: Comput Methods Programs Biomed Date: 2009-10-08 Impact factor: 5.428
Authors: Denis Tran; Allaudin A Kamani; Elias Al-Attas; Victoria A Lessoway; Simon Massey; Robert N Rohling Journal: Can J Anaesth Date: 2010-04 Impact factor: 5.063
Authors: Mikael Brudfors; Alexander Seitel; Abtin Rasoulian; Andras Lasso; Victoria A Lessoway; Jill Osborn; Atsuto Maki; Robert N Rohling; Purang Abolmaesumi Journal: Int J Comput Assist Radiol Surg Date: 2015-04-18 Impact factor: 2.924
Authors: Laxmaiah Manchikanti; Alan D Kaye; Mark V Boswell; Sanjay Bakshi; Christopher G Gharibo; Vahid Grami; Jay S Grider; Sanjeeva Gupta; Sachin Sunny Jha; Dharam P Mann; Devi E Nampiaparampil; Manohar Lal Sharma; Lindsay N Shroyer; Vijay Singh; Amol Soin; Ricardo Vallejo; Bradley W Wargo; Joshua A Hirsch Journal: Pain Physician Date: 2015 Jul-Aug Impact factor: 4.965
Authors: Filip Šroubek; Michal Bartoš; Jan Schier; Zuzana Bílková; Barbara Zitová; Jan Vydra; Iva Macová; Jan Daneš; Lukáš Lambert Journal: Int J Comput Assist Radiol Surg Date: 2019-01-23 Impact factor: 2.924
Authors: Javier Esteban; Walter Simson; Sebastian Requena Witzig; Anna Rienmüller; Salvatore Virga; Benjamin Frisch; Oliver Zettinig; Drazen Sakara; Yu-Mi Ryang; Nassir Navab; Christoph Hennersperger Journal: Int J Comput Assist Radiol Surg Date: 2018-04-18 Impact factor: 2.924