Literature DB >> 28235953

Nickel-associated delayed multiple white matter lesions after stent-assisted coil embolization of intracranial unruptured aneurysm.

Hun Soo Park1, Ichiro Nakagawa1, Shohei Yokoyama1, Daisuke Wajima1, Takeshi Wada2, Yasushi Motoyama1, Kimihiko Kichikawa2, Hiroyuki Nakase1.   

Abstract

Metal-induced encephalopathy after stent-assisted coil embolization is extremely rare. The present report describes two patients who presented with symptomatic intracranial parenchymal edematous lesions after stent-assisted coil embolization. A 64-year-old woman underwent stent-assisted coil embolization for a left internal carotid artery aneurysm; 21 days after the procedure she presented with right hand weakness and MRI revealed multifocal white matter lesions. Another woman aged 52 years underwent stent-assisted coil embolization for right vertebral artery aneurysm; 18 days after the procedure she presented with left-sided sensory disturbance and MRI demonstrated multiple white matter lesions. Treatment in both cases resulted in improvement of these lesions after steroid pulse therapy, and the patients had no associated morbidity 4 months after the procedures. Clinicians should monitor for neurologic symptoms and postoperative delayed radiologic parenchymal edematous changes associated with the metal allergic reaction after nitinol stent-assisted coil embolization. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

Entities:  

Keywords:  Aneurysm; Inflammatory Response; Stent

Mesh:

Substances:

Year:  2017        PMID: 28235953     DOI: 10.1136/neurintsurg-2017-013005.rep

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  3 in total

1.  Delayed Leukoencephalopathy: A Rare Complication after Coiling of Cerebral Aneurysms.

Authors:  A Ikemura; T Ishibashi; K Otani; I Yuki; T Kodama; I Kan; N Kato; Y Murayama
Journal:  AJNR Am J Neuroradiol       Date:  2020-01-30       Impact factor: 3.825

2.  Microcatheter Originating Debris during Neuroendovascular Procedures: Mechanism of Dislodgement and Its Prevention.

Authors:  I Kan; K Karagiozov; S Ito; S Sato; Y Murayama
Journal:  AJNR Am J Neuroradiol       Date:  2020-08-27       Impact factor: 3.825

3.  Refractory in-stent stenosis after flow diverter stenting associated with delayed cobalt allergic reaction.

Authors:  Shoko Fujii; Kyohei Fujita; Hiroto Yamaoka; Kazunori Miki; Sakyo Hirai; Shigeru Nemoto; Kazutaka Sumita
Journal:  J Neurointerv Surg       Date:  2021-08-25       Impact factor: 5.836

  3 in total