Literature DB >> 28235698

The effect of anterior longitudinal ligament resection on lordosis correction during minimally invasive lateral lumbar interbody fusion: Biomechanical and radiographic feasibility of an integrated spacer/plate interbody reconstruction device.

Choll Kim1, Jonathan A Harris2, Aditya Muzumdar3, Saif Khalil4, Joseph A Sclafani5, Kamshad Raiszadeh6, Brandon S Bucklen7.   

Abstract

BACKGROUND: Lateral lumbar interbody fusion is powerful for correcting degenerative conditions, yet sagittal correction remains limited by anterior longitudinal ligament tethering. Although lordosis has been restored via ligament release, biomechanical consequences remain unknown. Investigators examined radiographic and biomechanical of ligament release for restoration of lumbar lordosis.
METHODS: Six fresh-frozen human cadaveric spines (L3-S1) were tested: (Miller et al., 1988) intact; (Battie et al., 1995) 8mm spacer with intact anterior longitudinal ligament; (Cho et al., 2013) 8mm spacer without intact ligament following ligament resection; (Galbusera et al., 2013) 13mm lateral lumbar interbody fusion; (Goldstein et al., 2001) integrated 13mm spacer. Focal lordosis and range of motion were assessed by applying pure moments in flexion-extension, lateral bending, and axial rotation.
FINDINGS: Cadaveric radiographs showed significant improvement in lordosis correction following ligament resection (P<0.05). The 8mm spacer with ligament construct provided greatest stability relative to intact (P>0.05) but did little to restore lordosis. Ligament release significantly destabilized the spine relative to intact in all modes and 8mm with ligament in lateral bending and axial rotation (P<0.05). Integrated lateral lumbar interbody fusion following ligament resection did not significantly differ from intact or from 8mm with ligament in all testing modes (P>0.05).
INTERPRETATION: Lordosis corrected by lateral lumbar interbody fusion can be improved by anterior longitudinal ligament resection, but significant construct instability and potential implant migration/dislodgment may result. This study shows that an added integrated lateral fixation system can significantly improve construct stability. Long-term multicenter studies are needed.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anterior longitudinal ligament release; Integrated lateral interbody device; Minimally invasive surgery; Spine biomechanics

Mesh:

Year:  2017        PMID: 28235698     DOI: 10.1016/j.clinbiomech.2017.02.006

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

1.  Biomechanical in vitro comparison between anterior column realignment and pedicle subtraction osteotomy for severe sagittal imbalance correction.

Authors:  Luigi La Barbera; Hans-Joachim Wilke; Christian Liebsch; Tomaso Villa; Andrea Luca; Fabio Galbusera; Marco Brayda-Bruno
Journal:  Eur Spine J       Date:  2019-08-14       Impact factor: 3.134

2.  Expandable Lateral Lumbar Cages With Integrated Fixation: A Viable Option for Rostral Adjacent Segment Disease.

Authors:  Gregory M Malham; Carl M Blecher; Nigel R Munday; Ryan P Hamer
Journal:  Int J Spine Surg       Date:  2022-06-16

3.  Minimally Invasive Anterior Longitudinal Ligament Release for Anterior Column Realignment.

Authors:  Jakub Godzik; Bernardo de Andrada Pereira; Courtney Hemphill; Corey T Walker; Joshua T Wewel; Jay D Turner; Juan S Uribe
Journal:  Global Spine J       Date:  2020-05-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.