BACKGROUND: Success of colonoscopy is linked to the adequacy of bowel cleansing. Polyethylene glycol 4L (PEG 4L) solutions are widely used for colonic cleansing but with limitations concerning tolerability and acceptability. AIM: To demonstrate the equivalence of a new low-volume PEG containing citrates and simeticone (Clensia) versus a standard PEG 4L. METHODS: In this, multicentre, randomised, observer-blind trial, patients received either Clensia 2L or PEG 4L solution. Primary endpoint was the proportion of patients with colon cleansing evaluated as excellent or good. RESULTS:422 patients receivedClensia (n=213) or PEG 4L (n=209). Rate of excellent/good bowel cleansing was 73.6% and 72.3% in Clensia and PEG 4L group respectively. Clensia was demonstrated to be equivalent to PEG 4L. No SAEs were observed. Clensia showed better gastrointestinal tolerability (37.0% vs 25.4%). The acceptability was significantly better with Clensia in terms of proportion of subjects who felt no distress (Clensia 72.8% vs PEG 4L 63%, P=0.0314) and willingness-to-repeat (93.9% vs 82.2%, P=0.0002). The rate of optimal compliance was similar with both formulations (91.1% for Clensia vs 90.9% for PEG 4L, P=0.9388). CONCLUSIONS: The low-volume Clensia is equally effective and safe in bowel cleansing compared to the standard PEG 4L, with better gastrointestinal tolerability and acceptability.
RCT Entities:
BACKGROUND: Success of colonoscopy is linked to the adequacy of bowel cleansing. Polyethylene glycol 4L (PEG 4L) solutions are widely used for colonic cleansing but with limitations concerning tolerability and acceptability. AIM: To demonstrate the equivalence of a new low-volume PEG containing citrates and simeticone (Clensia) versus a standard PEG 4L. METHODS: In this, multicentre, randomised, observer-blind trial, patients received either Clensia 2L or PEG 4L solution. Primary endpoint was the proportion of patients with colon cleansing evaluated as excellent or good. RESULTS: 422 patients received Clensia (n=213) or PEG 4L (n=209). Rate of excellent/good bowel cleansing was 73.6% and 72.3% in Clensia and PEG 4L group respectively. Clensia was demonstrated to be equivalent to PEG 4L. No SAEs were observed. Clensia showed better gastrointestinal tolerability (37.0% vs 25.4%). The acceptability was significantly better with Clensia in terms of proportion of subjects who felt no distress (Clensia 72.8% vs PEG 4L 63%, P=0.0314) and willingness-to-repeat (93.9% vs 82.2%, P=0.0002). The rate of optimal compliance was similar with both formulations (91.1% for Clensia vs 90.9% for PEG 4L, P=0.9388). CONCLUSIONS: The low-volume Clensia is equally effective and safe in bowel cleansing compared to the standard PEG 4L, with better gastrointestinal tolerability and acceptability.
Authors: Milena Di Leo; Andrea Iannone; Monica Arena; Giuseppe Losurdo; Maria Angela Palamara; Giuseppe Iabichino; Pierluigi Consolo; Maria Rendina; Carmelo Luigiano; Alfredo Di Leo Journal: World J Gastroenterol Date: 2021-12-07 Impact factor: 5.742
Authors: Patrizia Kump; Cesare Hassan; Cristiano Spada; Eva Brownstone; Christian Datz; Michael Haefner; Friedrich Renner; Rainer Schoefl; Florian Schreiber Journal: Endosc Int Open Date: 2018-08-01