Literature DB >> 28233132

Computed Tomographic Angiography-Based Characterization of Source Blood Vessels for Nipple-Areola Complex Perfusion in Hypertrophic Breasts.

Hui Zheng1, Yingjun Su1, Minwen Zheng2, Jian Li2, E Bei2, Lihong Qiu1, Zhaoxiang Zhang1, Jian Geng1, Chenggang Yi3.   

Abstract

BACKGROUND: Current knowledge about the blood supply of the nipple-areola complex (NAC) has largely been derived from studies on cadavers or persons with breasts of normal size. The aim of this study was to identify and classify the NAC blood supply by computed tomographic angiography (CTA) examination in female volunteers with breast hypertrophy.
METHODS: CTA examination was performed on hypertrophic breasts of 23 female subjects. The main blood supplies were revealed through image data analyses. The dominant blood supply of the NAC and its vascular sources were identified and sorted. The detectable diameter threshold of blood vessels was set beyond 1.0 mm.
RESULTS: A total of 61 dominant blood vessels were identified. The source arteries were traced as the internal thoracic artery (ITA, 50.8%), lateral thoracic artery (LTA, 27.8%), thoracoacromial artery (TA, 14.8%), brachial artery (BA, 3.3%), and axillary artery (AA, 3.3%), and the corresponding reproducibility of these source vessels was 31, 37, 9, 4.3, and 4.3%, in all breasts. The intercostal artery (IA) was not identified as a dominant NAC supplying vessel in any CTA scan image. Twenty-six breasts had only one dominant artery, whereas 17 breasts showed multiple dominant blood supplies. Three breasts showed no dominant blood vessels of the NAC, with diameters greater than the detectable threshold of 1.0 mm, and 52.2% of the breasts demonstrated anatomically symmetrical patterns of blood supply for the NAC.
CONCLUSIONS: The ITA, LTA, and TA are likely to be the main vessel sources, whereas the IA is unlikely to be the dominant vessel for NAC perfusion, on the basis of the studied breasts. An asymmetrical pattern of bilateral breast blood supply was demonstrated in a considerable portion of the females with breast hypertrophy in this study. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Entities:  

Keywords:  Computed tomographic angiography; Hypertrophic breast; Main blood supply; Nipple–Areola complex

Mesh:

Year:  2017        PMID: 28233132     DOI: 10.1007/s00266-017-0791-5

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  4 in total

1.  Innovative Application of Three-Dimensional-Printed Breast Model-Aided Reduction Mammaplasty.

Authors:  Shaoheng Xiong; Bei E; Zhaoxiang Zhang; Jiezhang Tang; Xiangke Rong; Haibo Gong; Chenggang Yi
Journal:  Front Surg       Date:  2022-06-09

2.  Reliability and versatility of the Wise pattern, medial pedicle for breast reduction in South Africa.

Authors:  Marietha Nel; Elias Ndobe; Aylwyn Mannell; Letlhogonolo Brian Andrew Monaisa
Journal:  Surg Open Sci       Date:  2020-01-11

Review 3.  [Research progress in breast blood supply and breast reduction].

Authors:  Zhibin Yang; Facheng Li
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-07-15

4.  Evaluating the Image Quality of Monoenergetic Images From Dual-Energy Computed Tomography With Low-Concentration and Low-Flow-Rate Contrast Media for the Arterials Supply to the Nipple-Areola Complex in Breast Cancer Compared With Conventional Computed Tomography Angiography.

Authors:  Xiangfei Zeng; Xiaoxia Wang; Huifang Chen; Daihong Liu; Jinfang Shi; Jing Zhang; Xiaoqin Li; Liyin Zhang; Yi Yang; Jiuquan Zhang
Journal:  J Comput Assist Tomogr       Date:  2020 Nov/Dec       Impact factor: 2.081

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.