Literature DB >> 28231875

Comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for analysis of toad skin.

Jia-Fu Li1, Xia Yan1, Yun-Long Wu1, Mei-Juan Fang1, Zhen Wu1, Ying-Kun Qiu2.   

Abstract

An analytical two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was constructed with a newly developed thermal evaporation assisted adsorption (TEAA) interface. This novel TEAA interface with heating temperature above solvent boiling point allowed fast removal of organic NPLC solvent and successfully solved the solvent incompatibility problem between NPLC and RPLC. The system achieved rapid on-line solvent exchange between the two dimensions within a short modulation time of 190 s and was applied in the analysis of an extract from the skin of Bufo bufo gargarizans. This is the first time to realize the on-line comprehensive analysis of a moderate polar natural product by coupling NPLC with reversed phase ultra-high performance liquid chromatography (UHPLC). To be highlighted, with the TEAA interface, the 2D NPLC × RPLC system provided excellent resolution and orthogonality (75.2%), when compared with that of 2D RPLC × RPLC.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bufadienolides; Bufo bufo gargarizans; Thermal evaporation assisted adsorption interface; Toad skin; Two dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography

Mesh:

Year:  2017        PMID: 28231875     DOI: 10.1016/j.aca.2017.01.038

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Pyrene-Based Fluorescent Porous Organic Polymers for Recognition and Detection of Pesticides.

Authors:  Zhuojun Yan; Jinni Liu; Congke Miao; Pinjie Su; Guiyue Zheng; Bo Cui; Tongfei Geng; Jiating Fan; Zhiyi Yu; Naishun Bu; Ye Yuan; Lixin Xia
Journal:  Molecules       Date:  2021-12-26       Impact factor: 4.411

2.  [Size exclusion-reverse liquid column chromatography-mass spectrometry and its application in the identification of post-translationally modified proteins in rat kidney].

Authors:  Jianmin Li; Yue Zhuo; Yida Zhang; Na Li; Jianlin Wu
Journal:  Se Pu       Date:  2021-01

Review 3.  Optimizing separations in online comprehensive two-dimensional liquid chromatography.

Authors:  Bob W J Pirok; Andrea F G Gargano; Peter J Schoenmakers
Journal:  J Sep Sci       Date:  2017-11-23       Impact factor: 3.645

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.