James C Matthews1, Asan Bacak2, M Anwar H Khan3, Matthew D Wright4, Michael Priestley5, Damien Martin6, Carl J Percival7, Dudley E Shallcross8.
Abstract
People spend the majority of their time indoors and therefore the quality of indoor air is worthy of investigation; indoor air quality is affected by indoor sources of pollutants and from pollutants entering buildings from outdoors. In this study, unique perfluorocarbon tracers were released in five experiments at a 100 m and ~2 km distance from a large university building in Manchester, UK and tracer was also released inside the building to measure the amount of outdoor material penetrating into buildings and the flow of material within the building itself. Air samples of the tracer were taken in several rooms within the building, and a CO₂ tracer was used within the building to estimate air-exchange rates. Air-exchange rates were found to vary between 0.57 and 10.90 per hour. Indoor perfluorocarbon tracer concentrations were paired to outdoor tracer concentrations, and in-out ratios were found to vary between 0.01 and 3.6. The largest room with the lowest air-exchange rate exhibited elevated tracer concentrations for over 60 min after the release had finished, but generally had the lowest concentrations, the room with the highest ventilation rates had the highest concentration over 30 min, but the peak decayed more rapidly. Tracer concentrations indoors compared to outdoors imply that pollutants remain within buildings after they have cleared outside, which must be considered when evaluating human exposure to outdoor pollutants.Entities:
Keywords: air pollution; dispersion experiments; dynamics of indoor air contaminants; human exposure; indoor air quality (IAQ); indoor/outdoor ratio; infiltration; perfluorocarbons; tracer
Mesh:
Substances:
Year: 2017 PMID: 28230812 PMCID: PMC5334768 DOI: 10.3390/ijerph14020214
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Figure 1Tracer release and sampler locations used in the tracer experiments, November 2015–February 2016. (a) position of the test building (X) in Greater Manchester, UK; (b) the position of sampling locations in the area around the test building (indicated by the red square in (a,c) the view of the test building from Dover Street, looking North, and position of indoor samples. Release points are indicated by R1–R5, sampling positions 1–10 and the position of meteorological measurements indicated by W. Map images © OpenStreetMap contributors [27].
Spot measurements of air exchanges within selected rooms within the test building.
| Date | Time (British Summer Time) | Background CO2 Concentration (ppm) | Mass CO2 (g) | Room | Condition | Room Volume (m3) | Air-Exchanges per Hour |
|---|---|---|---|---|---|---|---|
| 20/09/2016 | 11:50 | 447 | 30 | Second floor aerosol lab | Closed room | 161 | 6.1 |
| 20/09/2016 | 13:05 | 452 | 100 | Second floor balcony lab | Balcony door closed | 138 | 4.2 |
| 20/09/2016 | 14:15 | 445 | 100 | Second floor balcony lab | Balcony door open | 138 | 3.9 |
| 20/09/2016 | 15:00 | 448 | 100 | Second floor lab | Closed room | 161 | 7.4 |
| 26/09/2016 | 18:43 | 451 | 100 | Fourth floor office | Window shut | 70 | 0.9 |
| 26/09/2016 | 20:45 | 415 | 100 | Fourth floor office | Window open | 70 | 10.9 |
| 26/09/2016 | 21:12 | 409 | 100 | Fourth floor office | Window ajar | 70 | 1.7 |
| 27/09/2016 | 00:40 | 423 | 100 | Fourth floor office | Window shut | 70 | 1.0 |
| 04/10/2016 | 02:25 | 429 | 200 | Ground floor lab | Closed room | n/a | 3.9 |
| 04/10/2016 | 03:10 | 463 | 300 | Ground floor lab | Closed room | n/a | 3.8 |
| 11/10/2016 | 22:10 | 512 | 1000 | Computer room | Overnight | 1475 | 0.6 |
Background concentrations of selected perfluorocarbons (PFCs) in parts per quadrillion (ppq). X denotes failed or unquantifiable sample.
| Date | Location | PMCH | mc-PDMCH | PMEP | |
|---|---|---|---|---|---|
| 30/10/2015 | Second floor aerosol lab (out) | 8.3 | 10.8 | 7.9 | |
| 30/10/2015 | Second floor aerosol lab (in) | 5.8 | 9.4 | X | |
| 30/10/2015 | Second floor balcony lab (in) | 5.6 | 9.8 | 6.3 | |
| 30/10/2015 | Second floor computing lab (in) | 7.8 | 11.3 | 4.6 | |
| 11/11/2015 | Second-floor aerosol lab (out) | 5.9 | 8.9 | X | |
| 11/11/2015 | Second floor aerosol lab (in) | 6.1 | 8.1 | X | |
| 11/11/2015 | Ground floor lobby (in) | 6.2 | 10.0 | X | |
| 11/11/2015 | Second floor aerosol lab (in) | 6.5 | 9.0 | X | |
| 22/02/2016 | Second floor aerosol lab (out) | 7.4 | 10.3 | X | |
| 22/02/2016 | Second floor aerosol lab (in) | 7.3 | 10.9 | X | |
| 23/02/2016 | Second floor aerosol lab (out) | 12.0 | 14.5 | X | |
| 23/02/2016 | Second floor aerosol lab (in) | 11.0 | 13.2 | X | |
| 23/02/2016 | Second floor aerosol lab (out) | 8.3 | 12.1 | X | |
| 23/02/2016 | Second floor aerosol lab (in) | 8.9 | 11.7 | X | |
| Mean | 7.6 | 10.7 | 6.2 | ||
| SD | 2.0 | 1.7 | 1.4 |
Times, release amounts and conditions during PFC releases.
| Date | Time (Greenwich Mean Time) | Location | Chemical | Release Mixture PFC Concentration (% by Volume) | Mass Released (mg) | Release Rate (mg∙s−1) |
|---|---|---|---|---|---|---|
| 30/10/2015 | 15:00–15:05 | R0 | PMEP | 1149.4 | 27.93 | 0.093 |
| 15:00–15:15 | R1 | mPDMCH | 1601.3 | 35.12 | 0.039 | |
| (mc-PDMCH) | −1006.7 | −22.08 | −0.025 | |||
| 15:00–15:15 | R4 | PMCH | 5643 | 1390.32 | 1.545 | |
| 11/11/2015 | 00:00–00:15 | R2 | mPDMCH | 1601.3 | 41.57 (26.14) | 0.046 |
| (mc-PDMCH) | −1006.7 | −0.029 | ||||
| 00:00–00:15 | R5 | PMCH | 5643 | 1297.11 | 1.441 | |
| 00:00–00:15 | R2 | mPDMCH | 1601.3 | 42.46 | 0.047 | |
| (mc-PDMCH) | −1006.7 | −26.69 | −0.03 | |||
| 23/02/2016 | 07:36–07:51 | R3 | mPDMCH | 1601.3 | 17.25 | 0.019 |
| (mc-PDMCH) | −1006.7 | −10.85 | −0.012 | |||
| 12:00–12:15 | R3 | mPDMCH | 1601.3 | 9.45 | 0.01 | |
| (mc-PDMCH) | −1006.7 | −5.94 | −0.007 |
Results (ppq above background) of tracer experiments. Tracer was released for 15 min, except PMEP release for 5 min, from a location upwind of the test building either 2 km away (PMCH), 100 m away (mc-PDMCH) or inside the building (PMEP). X indicates a failed sample and NS indicates a sample that was not significantly above background (defined as less than two SD of all background measurements).
| Location | 30/10/2015 15:00 PMEP | mc-PDMCH | PMCH | 11/11/2015 00:00 mc-PDMCH | PMCH | 11/11/2015 15:30 mc-PDMCH | 23/02/2016 07:00 mc-PDMCH | 23/02/2016 00:00 mc-PDMCH | |
|---|---|---|---|---|---|---|---|---|---|
| Daily mean BG (second floor balcony lab) | 6.2 | 10.3 | 6.9 | 10.6 | 6.0 | 9.0 | 13.6 | 11.9 | |
| 1 | Sixth floor computing lab (out) | 2.7 NS | 14.4 | 2.8 NS | 192.4 | 1.4 NS | 21.6 | 49.0 | 17.2 |
| 2 | Sixth floor computing lab (in) | 10.5 | 14.5 | 1.2 NS | 1.7 NS | 2.7 NS | 1.8 NS | 8.4 | 12.7 |
| 3 | Fourth floor office (out) | 1.7 NS | 11.3 | 1.9 NS | 10.6 | 1.6 NS | 30.4 | 130.1 | 23.1 |
| 4 | Fourth floor office (in) | 0 NS | 9.8 | 1.4 NS | 4.4 | 2.1 NS | 15.7 | 6.9 | X |
| 5 | Second floor balcony lab (out) | 8.8 | 2.4 NS | 6.3 | 71.2 | 20.2 | |||
| 6 | Second floor balcony lab (in) | 1.2 NS | 7.7 | 1.9 NS | 8.7 | 2.3 NS | 22.7 | 57.9 | 22.3 |
| 7 | Second floor aerosol lab (in) | 11.4 | 16.3 | 0 NS | 20.0 | 8.4 | 16.8 | 17.9 | 17.5 |
| 8 | Out west | 6.7 | 26.8 | 2.0 NS | X | X | 26.4 | 40.9 | 146.7 |
| 9 | Out east | X | X | 81.3 | 348.4 | 79.3 | |||
| 10 | Out north | 71.9 | 2.1 NS | 11.9 | 96.0 | 3.60 |
Average of three 10-min samples; Bag disconnected from sampler during experiment; Sampled indoor air for 13 min; Missed first 2 min of sample; Missed first 4 min of sample; Missed first 13 min of sample.
Figure 2Time series of tracer decay over 90 min for three rooms in the test building; (a) the aerosol lab was a small lab with closed windows; (b) the balcony lab was a small well-ventilated lab with an open door and (c) the computing lab was a larger room used by students. Solid lines indicate the measured PFC concentrations; dashed lines represent the line of significance (2 × standard deviation of all background measurements).
Times, and weather conditions during PFC releases, the values in parenthesis are standard deviations. X denotes that measurements were unavailable on that day.
| Date | Time (Greenwich Mean Time) | Vertical Wind Speed (m∙s−1) | Horizontal Wind Speed (m∙s−1) | Wind Direction | Temperature (°C) | Relative Humidity (%) | Pressure (hPa) |
|---|---|---|---|---|---|---|---|
| 30/10/2015 | 15:00–15:30 | −0.17 (0.29) | 3.36 (1.06) | S | 18 (0.0) | X | 1005.3 (0.2) |
| 30/10/2015 | 15:00–16:30 | −0.31 (0.42) | 4.54 (1.99) | S | 17.8 (0.2) | X | 1005.5 (0.2) |
| 11/11/2015 | 00:00–00:30 | −0.22 (0.33) | 4.20 (1.10) | SSW | 14.2 (0) | 86.5 (0.1) | 1006.4 (0.0) |
| 11/11/2015 | 15:30–16:00 | −0.30 (0.58) | 6.58 (2.22) | SW | 14.9 (0) | 78.2 (0.5) | 1104.3 (0.1) |
| 23/02/2016 | 07:30–08:00 | 0.01 (0.26) | 0.99 (0.52) | NNW | 9.2 (0.1) | 44.6 (1.5) | 1008.4 (0.0) |
| 23/02/2016 | 12:00–12:30 | 0.23 (0.49) | 2.14 (1.17) | NNW | 3.3 (0.1) | 88.3 (0.2) | 1005.8 (0.2) |
Figure 3Wind roses and maps showing position of release (R) and outdoor samples for five tracer experiments released in Manchester with wind speeds measured at 1 Hz. Concentrations are shown as percentages of maximum concentration measured on that day. Sample positions are at ground level, apart from the three positions measured outside rooms in the test building on the second, fourth and sixth floors, which are indicated by numbers. X indicates that a sample was not collected on that day. Map images © OpenStreetMap contributors [27].
Figure 4Ratio of tracer measured inside and outside three rooms within the test building for mc-PDMCH tracer released ~100 m away. Data excluded where samples were not recorded for the same length of time indoors and outdoors. The dashed line represents unity where indoor and outdoor concentrations are equal.
Figure 5Decay curve of CO2 and PFC tracer from point of maximum concentration, displayed as a percentage of maximum concentration for (a) the aerosol lab; (b) the balcony lab and (c) the computing lab in the test building.