Literature DB >> 28230344

Fully Automatic In-Syringe Magnetic Stirring-Assisted Dispersive Liquid-Liquid Microextraction Hyphenated to High-Temperature Torch Integrated Sample Introduction System-Inductively Coupled Plasma Spectrometer with Direct Injection of the Organic Phase.

Raquel Sánchez1, Burkhard Horstkotte2,3, Kateřina Fikarová2, Hana Sklenářová2, Salvador Maestre1, Manuel Miró2,3, Jose-Luis Todolí1.   

Abstract

A proof of concept study involving the online coupling of automatic dispersive liquid-liquid microextraction (DLLME) to inductively coupled plasma optical emission spectrometry (ICP OES) with direct introduction and analysis of the organic extract is herein reported for the first time. The flow-based analyzer features a lab-in-syringe (LIS) setup with an integrated stirring system, a Meinhard nebulizer in combination with a heated single-pass spray chamber, and a rotary injection valve, used as an online interface between the microextraction system and the detection instrument. Air-segmented flow was used for delivery of a fraction of the nonwater miscible extraction phase, 12 μL of xylene, to the nebulizer. All sample preparative steps including magnetic stirring assisted DLLME were carried out inside the syringe void volume as a size-adaptable yet sealed mixing and extraction chamber. Determination of trace level concentrations of cadmium, copper, lead, and silver as model analytes has been demonstrated by microextraction as diethyldithiophosphate (DDTP) complexes. The automatic LIS-DLLME method features quantitative metal extraction, even in troublesome sample matrixes, such as seawater, salt, and fruit juices, with relative recoveries within the range of 94-103%, 93-100%, and 92-99%, respectively. Furthermore, no statistically significant differences at the 0.05 significance level were found between concentration values experimentally obtained and the certified values of two serum standard reference materials.

Entities:  

Year:  2017        PMID: 28230344     DOI: 10.1021/acs.analchem.7b00400

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction for the determination of arsenic species in rice samples.

Authors:  Xiaojun Wang; Guoliang Xu; Peng Chen; Yueshu Sun; Xiaoting Yao; Yan Lv; Weiwei Guo; Guozhen Wang
Journal:  RSC Adv       Date:  2018-05-08       Impact factor: 3.361

2.  The Automation Technique Lab-In-Syringe: A Practical Guide.

Authors:  Burkhard Horstkotte; Petr Solich
Journal:  Molecules       Date:  2020-04-01       Impact factor: 4.411