Literature DB >> 28222872

Clinical marginal fit of zirconia crowns and patients' preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material.

Nawapat Sakornwimon1, Chalermpol Leevailoj2.   

Abstract

STATEMENT OF PROBLEM: The use of digital intraoral scanners is increasing; however, evidence of its precision in making crown impressions clinically remains scarce. Patients should also feel more comfortable with digital impressions, but only a few studies evaluating this subject have been performed.
PURPOSE: The purpose of this clinical study was to evaluate the marginal fit of monolithic zirconia crowns and patients' preferences for digital impressions versus polyvinyl siloxane (PVS) impressions.
MATERIAL AND METHODS: Sixteen participants with indications for single molar crowns were included. After crown preparation, digital impressions by intraoral scanner and PVS impressions were made. The participants were asked to complete a 6-item questionnaire with a visual analog scale related to perceptions of each of the following topics: time involved, taste/smell, occlusal registration, size of impression tray/scanner, gag reflex, and overall preference. Computer-aided design and computer-aided manufacturing monolithic zirconia crowns were fabricated from both impressions. The crowns were evaluated intraorally, and a blinded examiner measured the marginal discrepancy of silicone replicas under a stereomicroscope. Intraexaminer reliability was evaluated by calculating the intraclass correlation coefficient. Data for patients' preferences and marginal discrepancies were analyzed using the paired t test (α=.05).
RESULTS: Visual analog scale scores for digital impressions were statistically significantly higher than those for PVS impressions in every topic (P<.05), except for occlusal registration. The results showed excellent reliability of the examiner with an intraclass correlation coefficient of .996. No significant difference was found in marginal discrepancies between the PVS group and the digital group on all sides (P>.05).
CONCLUSIONS: No differences were found in the clinical marginal fit of zirconia crowns fabricated from either digital impressions compared with PVS impressions. Furthermore, patients' satisfaction with digital impressions was significantly higher than with conventional impressions.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28222872     DOI: 10.1016/j.prosdent.2016.10.019

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  13 in total

Review 1.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

Review 2.  3D Digital Impression Systems Compared with Traditional Techniques in Dentistry: A Recent Data Systematic Review.

Authors:  Marco Cicciù; Luca Fiorillo; Cesare D'Amico; Dario Gambino; Emanuele Mario Amantia; Luigi Laino; Salvatore Crimi; Paola Campagna; Alberto Bianchi; Alan Scott Herford; Gabriele Cervino
Journal:  Materials (Basel)       Date:  2020-04-23       Impact factor: 3.623

3.  Digital vs. conventional workflow for one-abutment one-time immediate restoration in the esthetic zone: a randomized controlled trial.

Authors:  Brieuc Hanozin; Lou Li Manni; Geoffrey Lecloux; Miljana Bacevic; France Lambert
Journal:  Int J Implant Dent       Date:  2022-02-07

Review 4.  Ceramic Materials and Technologies Applied to Digital Works in Implant-Supported Restorative Dentistry.

Authors:  Se-Wook Pyo; Dae-Joon Kim; Jung-Suk Han; In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623

5.  Evaluation of marginal discrepancy of pressable ceramic veneer fabricated using CAD/CAM system: Additive and subtractive manufacturing.

Authors:  Seen-Young Kang; Ha-Na Lee; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

6.  Accuracy on Scanned Images of Full Arch Models with Orthodontic Brackets by Various Intraoral Scanners in the Presence of Artificial Saliva.

Authors:  Jihu Song; Minji Kim
Journal:  Biomed Res Int       Date:  2020-02-27       Impact factor: 3.411

7.  Reliability of a Virtual Prosthodontic Project Realized through a 2D and 3D Photographic Acquisition: An Experimental Study on the Accuracy of Different Digital Systems.

Authors:  Luca Lavorgna; Gabriele Cervino; Luca Fiorillo; Giovanni Di Leo; Giuseppe Troiano; Marco Ortensi; Luigi Galantucci; Marco Cicciù
Journal:  Int J Environ Res Public Health       Date:  2019-12-16       Impact factor: 3.390

8.  A Comparison of Full Arch Trueness and Precision of Nine Intra-Oral Digital Scanners and Four Lab Digital Scanners.

Authors:  Adam B Nulty
Journal:  Dent J (Basel)       Date:  2021-06-23

9.  Prospective Clinical Evaluation of Posterior Third-Generation Monolithic Zirconia Crowns Fabricated with Complete Digital Workflow: Two-Year Follow-Up.

Authors:  Mustafa Gseibat; Pablo Sevilla; Carlos Lopez-Suarez; Verónica Rodríguez; Jesús Peláez; María J Suárez
Journal:  Materials (Basel)       Date:  2022-01-17       Impact factor: 3.623

10.  Marginal and internal fit of crowns based on additive or subtractive manufacturing.

Authors:  Yasser Haddadi; Bahram Ranjkesh; Flemming Isidor; Golnosh Bahrami
Journal:  Biomater Investig Dent       Date:  2021-06-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.