[Pediatric hearing rehabilitation with the Baha® Attract implant system].

Bálint Posta1, János András Jarabin1, Ádám Perényi1, Zsófia Bere1, Adriana Neagos2, Ferenc Tóth1, József Géza Kiss1, László Rovó1.   

Abstract

INTRODUCTION: Baha® Attract is a new transcutaneous bone-conduction hearing aid, which is more preferable in childhood than the conventional percutaneous systems. AIM: Our aim was to demonstrate the possibilities of application in childhood.
METHOD: Eight children have undergone surgeries (mean age of 13.2 ± 3.2 years; "posterosuperior" incision technique, 5 mm implants). The thickness of the skull bone was determined in 72 children (1-8 years old) at the recommended implant site, based on CT scans.
RESULTS: The average duration of surgeries was 30 minutes. There were no intra- and postoperative complications observed. Sound processors were fitted at the postoperative 4th week. Hearing measurements proved 51.58±11.22SD dBHL gain in warble tone thresholds, and 43.3 ± 16.02 SD dB in speech discrimination thresholds. The skull bone thickness was measured as 3.39 ± 1.05 SD mm.
CONCLUSION: The Baha Attract system is a new tool for hearing rehabilitation in pediatric population. Preoperative CT provides valuable knowledge about skull bone thickness. Orv. Hetil., 2017, 158(8), 304-310.

Entities:  

Keywords:  Baha® Attract; bone conduction; childhood application; csontvezetés; gyermekkori alkalmazás; transcutan; transcutaneous

Mesh:

Year:  2017        PMID: 28218563     DOI: 10.1556/650.2017.30675

Source DB:  PubMed          Journal:  Orv Hetil        ISSN: 0030-6002            Impact factor:   0.540


  3 in total

1.  Comparison of two different bone anchored hearing instruments.

Authors:  Ahmet Kara; Mahmut Tayyar Kalcioglu; Çağlayan Adigul; Merve Torun Topcu; Mehmet Koçoğlu; Bilgehan Celik; Mahmut Sinan Yilmaz
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-10-10       Impact factor: 3.236

2.  Pediatric morphometric study to guide the optimized implantation of the Osia® 2 implant system.

Authors:  Balint Posta; Adam Perenyi; Linda Szabo; Roland Nagy; Gabor Katona; Zsuzsanna Csakanyi; Laszlo Rovo; Zsofia Bere
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-03-16       Impact factor: 3.236

3.  Early experience on a modern, thin cochlear implant family. A retrospective, international multicenter study.

Authors:  A Perenyi; F Toth; A A Nagy; J Skrivan; J Boucek; D C Gheorghe; A Neagos; J G Kiss; J Jori; L Rovo
Journal:  J Med Life       Date:  2018 Apr-Jun
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.