Literature DB >> 28218371

Adverse reaction to metal debris in a consecutive series of DUROM™ hip resurfacing: pseudotumour incidence and metal ion concentration.

Albrecht Hartmann1, Jan-Dirk Kieback2, Jörg Lützner1, Klaus-Peter Günther1, Jens Goronzy1.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the incidence of adverse reactions to metal debris (ARMD) in a consecutive series of DUROM™ Hip Resurfacing Arthroplasty (HRA) at mid-term follow-up.
METHODS: Between October 2003 and March 2007 a total of 134 consecutive DUROM™ HRA in 121 patients were performed at our institution. Follow-up could be obtained in 101 unrevised patients (83%) at a mean time of 8.51 ± 0.97 years postoperatively and included patient-related outcome measurement, plain radiographs, MARS-MRI as well as whole blood metal ion assessment.
RESULTS: 17 (16.5%) out of 103 hips revealed pseudotumour occurrence in MRI investigation, 1 (10.6%) with a diameter of ≥2 cm. Higher incidence of pseudotumours was found patients with femoral component size <50 mm. 38 patients had elevated cobalt levels, 36 of them (35%) in the range of 2-7 μg/l and 2 patients (1.9%) at a rate of >7 μg/l. In contrast to cobalt determination, only elevated chromium values showed a positive association with pseudotumour occurrence and size. DISCUSSION: A significant proportion of patients developed pseudotumours and metal ion elevation in a consecutive cohort of DUROM™ HRA after mid-term follow-up. The incidence, however, seems not to differ from results of other well performing resurfacing brands; clinical relevance of our findings is unclear. Regarding potential local as well as systemic effects of metal particle release, close follow-up of patients is essential, even with clinically well-performing implants.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28218371     DOI: 10.5301/hipint.5000468

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  3 in total

1.  Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study.

Authors:  Anne Postler; Franziska Beyer; Cornelia Lützner; Eric Tille; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-03       Impact factor: 4.342

2.  [The use of knee prostheses with a hypoallergenic coating is safe in the medium term : A randomized controlled study].

Authors:  Anne Postler; Franziska Beyer; Cornelia Lützner; Eric Tille; Jörg Lützner
Journal:  Orthopadie (Heidelb)       Date:  2021-11-03

3.  Large Soft-tissue Mass Formation After Revision Total Knee Arthroplasty: An Unusual Case of Adverse Reaction to Metal Debris and Review of the Literature.

Authors:  Petri Bellova; Jessica Pablik; Maik Stiehler; Adrian Dragu; Jörg Lützner
Journal:  Arthroplast Today       Date:  2021-06-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.