Literature DB >> 28217778

A critical insight into the development pipeline of microfluidic immunoassay devices for the sensitive quantitation of protein biomarkers at the point of care.

Ana I Barbosa1, Nuno M Reis2.   

Abstract

The latest clinical procedures for the timely and cost-effective diagnosis of chronic and acute clinical conditions, such as cardiovascular diseases, cancer, chronic respiratory diseases, diabetes or sepsis (i.e. the biggest causes of death worldwide), involve the quantitation of specific protein biomarkers released into the blood stream or other physiological fluids (e.g. urine or saliva). The clinical thresholds are usually in the femtomolar to picolomar range, and consequently the measurement of these protein biomarkers heavily relies on highly sophisticated, bulky and automated equipment in centralised pathology laboratories. The first microfluidic devices capable of measuring protein biomarkers in miniaturised immunoassays were presented nearly two decades ago and promised to revolutionise point-of-care (POC) testing by offering unmatched sensitivity and automation in a compact POC format; however, the development and adoption of microfluidic protein biomarker tests has fallen behind expectations. This review presents a detailed critical overview into the pipeline of microfluidic devices developed in the period 2005-2016 capable of measuring protein biomarkers from the pM to fM range in formats compatible with POC testing, with a particular focus on the use of affordable microfluidic materials and compact low-cost signal interrogation. The integration of these two important features (essential unique selling points for the successful microfluidic diagnostic products) has been missed in previous review articles and explain the poor adoption of microfluidic technologies in this field. Most current miniaturised devices compromise either on the affordability, compactness and/or performance of the test, making current tests unsuitable for the POC measurement of protein biomarkers. Seven core technical areas, including (i) the selected strategy for antibody immobilisation, (ii) the surface area and surface-area-to-volume ratio, (iii) surface passivation, (iv) the biological matrix interference, (v) fluid control, (vi) the signal detection modes and (vii) the affordability of the manufacturing process and detection system, were identified as the key to the effective development of a sensitive and affordable microfluidic protein biomarker POC test.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28217778     DOI: 10.1039/c6an02445a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  19 in total

1.  Microfluidic communicating vessel chip for expedited and automated immunomagnetic assays.

Authors:  Yang Yang; Yong Zeng
Journal:  Lab Chip       Date:  2018-12-04       Impact factor: 6.799

2.  Biosensors Advances: Contributions to Cancer Diagnostics and Treatment.

Authors:  Ana I Barbosa; Rita Rebelo; Rui L Reis; Vitor M Correlo
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

3.  Multichannel dual protein sensing using amphiphilic supramolecular assemblies.

Authors:  Jingjing Gao; Theeraphop Prachyathipsakul; S Thayumanavan
Journal:  Chem Commun (Camb)       Date:  2021-11-30       Impact factor: 6.222

4.  Protein and Proteome Measurements with Microfluidic Chips.

Authors:  Iulia M Lazar; Nicholas S Gulakowski; Alexandru C Lazar
Journal:  Anal Chem       Date:  2019-11-12       Impact factor: 6.986

5.  Reagent integration and controlled release for multiplexed nucleic acid testing in disposable thermoplastic 2D microwell arrays.

Authors:  S Padmanabhan; A Sposito; M Yeh; M Everitt; I White; D L DeVoe
Journal:  Biomicrofluidics       Date:  2021-01-15       Impact factor: 2.800

6.  Composable Microfluidic Plates (cPlate): A Simple and Scalable Fluid Manipulation System for Multiplexed Enzyme-Linked Immunosorbent Assay (ELISA).

Authors:  Ziyi He; Justin Huffman; Kathrine Curtin; Krista L Garner; Elizabeth C Bowdridge; Xiaojun Li; Timothy R Nurkiewicz; Peng Li
Journal:  Anal Chem       Date:  2020-12-16       Impact factor: 6.986

7.  A Portable Magnetic Particle Spectrometer for Future Rapid and Wash-Free Bioassays.

Authors:  Kai Wu; Vinit Kumar Chugh; Arturo di Girolamo; Jinming Liu; Renata Saha; Diqing Su; Venkatramana D Krishna; Abilash Nair; Will Davies; Yongqiang Andrew Wang; Maxim C-J Cheeran; Jian-Ping Wang
Journal:  ACS Appl Mater Interfaces       Date:  2021-02-10       Impact factor: 10.383

Review 8.  Biomarkers for Point-of-Care Diagnosis of Sepsis.

Authors:  Andrew Teggert; Harish Datta; Zulfiqur Ali
Journal:  Micromachines (Basel)       Date:  2020-03-10       Impact factor: 2.891

9.  Development and Evaluation of a Quantitative Fluorescent Lateral Flow Immunoassay for Cystatin-C, a Renal Dysfunction Biomarker.

Authors:  Satheesh Natarajan; Maria C DeRosa; Malay Ilesh Shah; Joseph Jayaraj
Journal:  Sensors (Basel)       Date:  2021-05-03       Impact factor: 3.576

10.  A Novel Microfluidic Point-of-Care Biosensor System on Printed Circuit Board for Cytokine Detection.

Authors:  Daniel Evans; Konstantinos I Papadimitriou; Nikolaos Vasilakis; Panagiotis Pantelidis; Peter Kelleher; Hywel Morgan; Themistoklis Prodromakis
Journal:  Sensors (Basel)       Date:  2018-11-17       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.