Literature DB >> 28215568

Reduction in radiation dose for atrial fibrillation ablation over time: A 12-year single-center experience of 2344 patients.

Aleksandr Voskoboinik1, Elana S Kalman2, Yonatan Savicky2, Paul B Sparks3, Joseph B Morton3, Geoffrey Lee3, Peter M Kistler4, Jonathan M Kalman5.   

Abstract

BACKGROUND: Pulmonary vein isolation (PVI) is a well-established treatment of atrial fibrillation (AF), with contact force (CF)-sensing catheters joining 3-dimensional mapping systems and image integration as technological advancements over the last decade.
OBJECTIVE: The purpose of this study was to analyze trends in radiation exposure for AF ablation over the last 12 years at our center.
METHODS: We reviewed prospectively collected data of 2344 consecutive PVI procedures for either paroxysmal or persistent AF between January 2004 and December 2015. During this period, all cases used 3-dimensional mapping systems, with 8 software and 2 hardware upgrades. Primary endpoints were fluoroscopy time, absorbed dose (Air Kerma in mGy), and effective dose (mSv).
RESULTS: In total, 1914 patients underwent initial PVI, and 430 patients underwent redo PVI using radiofrequency energy. Fluoroscopy time, and absorbed and effective doses significantly and progressively decreased over the 12-year period for initial PVI as follows: 2004-2006: 61 ± 27 minutes; 2007-2009: 46 ± 14 minutes, 1365 ± 1369 mGy, 11.3 ± 12.5 mSv; 2010-2012: 31 ± 11, 464 ± 339 mGy, 9.0 ± 10.4 mSv; and 2013-2015: 17 ± 9 minutes, 304 ± 758 mGy, 5.5 ± 6.7 mSv. CF-sensing catheters were used for 357/508 PVI only cases between 2014 and 2015. Fluoroscopy times (11 ± 5 vs 21 ± 8 minutes; P <.001) and absorbed dose (200 ± 524 vs 470 ± 1326 mGy; P = .004) were significantly shorter with this catheter.
CONCLUSION: Radiation exposure has dramatically decreased over the last decade for PVI and is related to operator experience, annual case volume, technology evolution, and more recently CF-sensing catheters. This has significant implications for both patient and operator long-term risk.
Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Ablation; Atrial fibrillation; Contact force; Fluoroscopy; Radiation

Mesh:

Year:  2017        PMID: 28215568     DOI: 10.1016/j.hrthm.2017.02.014

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  8 in total

1.  Safety and efficacy of zero fluoroscopy transseptal puncture with different approaches.

Authors:  Tina Baykaner; Kenneth K Quadros; Amit Thosani; Babak Yasmeh; Raman Mitra; Emerson Liu; William Belden; Zhigang Liu; Alex Costea; Chad R Brodt; Paul C Zei
Journal:  Pacing Clin Electrophysiol       Date:  2019-12-23       Impact factor: 1.976

2.  Atrial Fibrillation Ablation Without Fluoroscopy: Because We Can.

Authors:  Rahul N Doshi
Journal:  J Innov Card Rhythm Manag       Date:  2018-11-15

3.  X-Ray Exposure in Cardiac Electrophysiology: A Retrospective Analysis in 8150 Patients Over 7 Years of Activity in a Modern, Large-Volume Laboratory.

Authors:  Michela Casella; Antonio Dello Russo; Eleonora Russo; Valentina Catto; Francesca Pizzamiglio; Martina Zucchetti; Benedetta Majocchi; Stefania Riva; Giulia Vettor; Maria Antonietta Dessanai; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Carlo Vignati; Sergio Conti; Alice Bonomi; Corrado Carbucicchio; Luigi Di Biase; Andrea Natale; Claudio Tondo
Journal:  J Am Heart Assoc       Date:  2018-05-22       Impact factor: 5.501

4.  Atrial fibrillation ablation with a spring sensor-irrigated contact force-sensing catheter compared with other ablation catheters: systematic literature review and meta-analysis.

Authors:  Laurent Macle; Diana Frame; Larry M Gache; George Monir; Scott J Pollak; Lee Ming Boo
Journal:  BMJ Open       Date:  2019-06-11       Impact factor: 2.692

5.  Advancements in Radiofrequency Ablation of Cardiac Arrhythmias Open New Possibilities for Procedural Safety.

Authors:  Junaid Bhutto; Rahul N Doshi
Journal:  J Innov Card Rhythm Manag       Date:  2020-11-15

6.  Safety and Efficacy of Minimal- versus Zero-fluoroscopy Radiofrequency Catheter Ablation for Atrial Fibrillation: A Multicenter, Prospective Study.

Authors:  Paul C Zei; Kenneth K Quadros; Paul Clopton; Amit Thosani; John Ferguson; Chad Brodt; Geraldine O'Riordan; Mattheus Ramsis; Raman Mitra; Tina Baykaner
Journal:  J Innov Card Rhythm Manag       Date:  2020-11-15

7.  Two Year, Single Center Clinical Outcome After Catheter Ablation For Paroxysmal Atrial Fibrillation Guided by Lesion Index.

Authors:  Sri Sundaram; William Choe; J Ryan Jordan; Charles Boorman; Nate Mullins; Austin Davies; Austin Stucky; Sunil Nath
Journal:  J Atr Fibrillation       Date:  2018-06-30

8.  SANS FLUORO Optimized: A Case Report of Pulmonary Vein Isolation in a Patient with Cardiac Resynchronization Therapy Defibrillator and the Optimizer™ III Device.

Authors:  Hyacinth C Percell; Lynn Saeger; Erin Sharpe; Rose Saalfeld; Robert L Percell
Journal:  J Innov Card Rhythm Manag       Date:  2020-05-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.