Literature DB >> 28215461

The use of ultrasound for postoperative monitoring of cerebral bypass grafts: A technical report.

Ryan P Morton1, Isaac Joshua Abecassis2, Anne E Moore2, Cory M Kelly2, Michael R Levitt3, Louis J Kim4, Laligam N Sekhar2.   

Abstract

Duplex ultrasound and transcranial Doppler are valuable tools for post-operative monitoring of extracranial-intracranial cerebral bypass grafts. Here we describe our technique for the evaluation of both high-flow and low-flow cerebral bypass grafts over a nine year period. 186 bypass grafts were studied daily during the inpatient period between Jan 2005 and Dec 2014 after surgery for various cerebrovascular pathologies. There was a technical success rate of 97%. Duplex ultrasonographic flow measurements had excellent interobserver reliability with an intraclass correlation coefficient (ICC) of 0.89 (p=0.009). Technical nuances are highlighted and a brief discussion of pathology is undertaken.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Keywords:  Duplex; EC-IC bypass; Flow; Transcranial Doppler; Ultrasound; Vasospasm

Mesh:

Year:  2017        PMID: 28215461     DOI: 10.1016/j.jocn.2017.01.030

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  2 in total

1.  Safety, Feasibility, and Patient-Rated Outcome of Sonolucent Cranioplasty in Extracranial-Intracranial Bypass Surgery to Allow for Transcranioplasty Ultrasound Assessment.

Authors:  Alex R Flores; Visish M Srinivasan; Jill Seeley; Charity Huggins; Peter Kan; Jan-Karl Burkhardt
Journal:  World Neurosurg       Date:  2020-08-20       Impact factor: 2.104

2.  Elective Sonolucent Cranioplasty for Real-Time Ultrasound Monitoring of Flow and Patency of an Extra- to Intracranial Bypass.

Authors:  Caroline Hadley; Robert North; Visish Srinivasan; Peter Kan; Jan-Karl Burkhardt
Journal:  J Craniofac Surg       Date:  2020 May/Jun       Impact factor: 1.172

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.