| Literature DB >> 28215461 |
Ryan P Morton1, Isaac Joshua Abecassis2, Anne E Moore2, Cory M Kelly2, Michael R Levitt3, Louis J Kim4, Laligam N Sekhar2.
Abstract
Duplex ultrasound and transcranial Doppler are valuable tools for post-operative monitoring of extracranial-intracranial cerebral bypass grafts. Here we describe our technique for the evaluation of both high-flow and low-flow cerebral bypass grafts over a nine year period. 186 bypass grafts were studied daily during the inpatient period between Jan 2005 and Dec 2014 after surgery for various cerebrovascular pathologies. There was a technical success rate of 97%. Duplex ultrasonographic flow measurements had excellent interobserver reliability with an intraclass correlation coefficient (ICC) of 0.89 (p=0.009). Technical nuances are highlighted and a brief discussion of pathology is undertaken.Keywords: Duplex; EC-IC bypass; Flow; Transcranial Doppler; Ultrasound; Vasospasm
Mesh:
Year: 2017 PMID: 28215461 DOI: 10.1016/j.jocn.2017.01.030
Source DB: PubMed Journal: J Clin Neurosci ISSN: 0967-5868 Impact factor: 1.961