Literature DB >> 28213949

Peri-implant bone remodeling at the interface of three different implant types: a histomorphometric study in mini-pigs.

Wenjuan Zhou1,2,3, Sonja Kuderer2,4, Zhonghao Liu1, Christian Ulm2,4, Xiaohui Rausch-Fan3, Stefan Tangl2,4.   

Abstract

OBJECTIVES: The aim of this study was to perform a histomorphometric evaluation of the healing characteristics and jawbone remodeling processes in the peri-implant bone tissue of three commonly used implant surfaces, during the early weeks of osseointegration.
MATERIAL AND METHODS: Dental implants with three different surfaces (anodically modified, hydroxyapatite (HA)-coated and machined) were inserted into the mandibular side-tooth region of twelve adult mini-pigs. Histomorphometric analyses were performed to evaluate remodeling processes 3, 6 and 12 weeks post-implantation.
RESULTS: Only a few very early bone remodeling-resorption sites were found at 3 weeks. After 6 weeks, additional signs of remodeling-related reversal and bone formation were detectable in all three groups, which steadily increased until 12 weeks. At the latter time point, the amount of remodeled bone was significantly higher for the anodized and HA-coated surfaces than for the machined implants.
CONCLUSION: The results of this study demonstrate that peri-implant bone remodeling can start as early as 3 weeks after implantation and continues at a substantial level up to 12 weeks. The anodic modification or HA coating of implant surfaces appears to accelerate the conversion of primary regenerated bone into more mature secondary lamellar bone. If this observation is of clinical relevance, it has to be clarified in studies that include longer observational time periods.
© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bone remodeling; dental implants; histomorphometry; implant surface

Mesh:

Year:  2017        PMID: 28213949     DOI: 10.1111/clr.13009

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

1.  Effect of Different Surface Treatments on Titanium Dental Implant Micro-Morphology.

Authors:  Gaetano Marenzi; Filomena Impero; Fabio Scherillo; Josè Camilla Sammartino; Antonino Squillace; Gianrico Spagnuolo
Journal:  Materials (Basel)       Date:  2019-03-04       Impact factor: 3.623

2.  Establishment and Simulation of 3D Geometric Models of Mini-Pig and Sheep Knee Joints Using Finite Element Analysis.

Authors:  Peng-Fei Han; Rong Zhang; Yang-Yang Gao; Pengcui Li; Xiao-Chun Wei; Zhi Lv
Journal:  Med Sci Monit       Date:  2020-03-03

3.  The Use of ESEM-EDX as an Innovative Tool to Analyze the Mineral Structure of Peri-Implant Human Bone.

Authors:  Carlo Prati; Fausto Zamparini; Daniele Botticelli; Mauro Ferri; Daichi Yonezawa; Adriano Piattelli; Maria Giovanna Gandolfi
Journal:  Materials (Basel)       Date:  2020-04-03       Impact factor: 3.623

  3 in total