Literature DB >> 28213249

On-line flow injection molecularly imprinted solid phase extraction for the preconcentration and determination of 1-hydroxypyrene in urine samples.

Montserrat Serrano1, Mónica Bartolomé1, Juan Carlos Bravo1, Gema Paniagua1, Judith Gañan2, Alejandrina Gallego-Picó3, Rosa María Garcinuño1.   

Abstract

New analytical strategies tend to automation of sample pre-treatment and flow analysis techniques provided a number of enhanced analytical methods allowing high throughput. Flow techniques are usually faster, more robust and more flexible than their batch equivalents. In addition, flow methods use less sample and reagent amounts and reduce analytical costs and waste. A flow injection solid-phase extraction pre-concentration system using a molecularly imprinted polymer (MIP) packed micro-column was developed for the determination of 1-hydroxypyrene in human urine with fluorescence detection. The pre-concentration of 1-hydroxypyrene on the MIP was carried out based on the specific retention of analyte by on-line introducing the sample into the micro-column system. Methanol and dichloromethane mixture was used to elute the retained analyte for fluorometric analysis. Important influencing factors were studied in detail, in batch and in flow (MISPE procedure optimisation, sample and eluent volumes, flow rate, dimensions of MIP micro-column and amounts of packing material, etc). To the best of our knowledge, this is the first on-line flow injection molecularly imprinted solid phase extraction for the pre-concentration and determination of hydroxylate PAH metabolite in urine samples. The optimised method was successfully applied to the determination of 1-Hydroxypyrene in spiked urine samples, with recoveries in the range of 74-85% and RSD<4.6%. Under optimum experimental conditions, the linearity concentration range used was 10-400μgL-1, R2>0.996. We obtained limit of detection and quantification of 3.1μgL-1 and 10.5μgL-1, respectively. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  1-Hydroxypyrene; Flow injection analysis; Human urine; Molecularly imprinted polymer; On-line solid-phase extraction

Mesh:

Substances:

Year:  2016        PMID: 28213249     DOI: 10.1016/j.talanta.2016.01.048

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Assay of 1-hydroxypyrene via aggregation-induced quenching of the fluorescence of protamine-modified gold nanoclusters and 9-hydroxyphenanthrene-based sensitization.

Authors:  Jin-Hua Xue; Ling Liu; Yong-Sheng Wang; Jia-Qian Li; Mei Li; Yue-Ning Qu; Le Li
Journal:  Mikrochim Acta       Date:  2019-10-16       Impact factor: 5.833

2.  [Determination of three urinary catecholamines and serotonin by on-line packed-fiber solid-phase extraction].

Authors:  Yueling Bi; Tong Xu; Liqin Chen
Journal:  Se Pu       Date:  2021-12

3.  The Effect of the Synthesis Method on Physicochemical Properties of Selective Granular Polymer Sorbents.

Authors:  Alexandra Osipenko; Irina Garkushina
Journal:  Polymers (Basel)       Date:  2022-01-17       Impact factor: 4.329

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.