Literature DB >> 28211116

AC dielectrophoretic manipulation and electroporation of vaccinia virus using carbon nanoelectrode arrays.

Foram Ranjeet Madiyar1,2, Sherry L Haller3, Omer Farooq1, Stefan Rothenburg4, Christopher Culbertson2, Jun Li2,5.   

Abstract

This paper reports the capture and detection of vaccinia virus particles based on AC dielectrophoresis (DEP) and electrochemical impedance measurements employing an embedded vertically aligned carbon nanofiber (VACNF) nanoelectrode array (NEA) versus a macroscopic indium-tin-oxide (ITO) transparent electrode in a "points-and-lid" configuration. The nano-DEP device was fabricated by bonding two SU-8 covered electrodes patterned using photolithography. The bottom electrode contains a 200 × 200 μm2 active region on a randomly distributed NEA and the top electrode contains a microfluidic channel in SU-8 spin-coated on ITO to guide the flow of the virus solution. The real-time impedance change was measured during DEP capture and validated with fluorescence microscopy measurements. The NEA was able to capture virus particles with a rather low AC voltage (∼8.0 V peak-to-peak) at 1.0 kHz frequency as the particles were passed through the fluidic channel at high flow velocities (up to 8.0 mm/s). A concentration detection limit as low as ∼2.58 × 103 particles/mL was obtained via impedance measurements after only 54 sec of DEP capture. At the low AC frequencies (50.0 Hz or less), the high electric field at the exposed VACNF tips induced electroporation of the DEP-captured virus particles, which was validated by fluorescence emission from the dyes staining lipophilic membrane and internal nucleic acid, respectively. This study suggests the possibility of integration of a fully functional electronic device for rapid, reversible and label-free capture and detection of pathogenic viruses, with a potential of generating electroporation to the captured the virus particles for further biochemical study.
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Dielectrophoresis; Electroporation; Microfluidic; Nanoelectrode array; Real-time impedance; Vaccinia virus; Vertically aligned carbon nanofibers

Mesh:

Substances:

Year:  2017        PMID: 28211116     DOI: 10.1002/elps.201600436

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  3 in total

1.  Electrochemical Activity Assay for Protease Analysis Using Carbon Nanofiber Nanoelectrode Arrays.

Authors:  Yang Song; Huafang Fan; Morgan J Anderson; Jestin Gage Wright; Duy H Hua; Jessica Koehne; M Meyyappan; Jun Li
Journal:  Anal Chem       Date:  2019-02-15       Impact factor: 6.986

Review 2.  The latest advances on nonlinear insulator-based electrokinetic microsystems under direct current and low-frequency alternating current fields: a review.

Authors:  Blanca H Lapizco-Encinas
Journal:  Anal Bioanal Chem       Date:  2021-10-19       Impact factor: 4.142

Review 3.  Methods of Generating Dielectrophoretic Force for Microfluidic Manipulation of Bioparticles.

Authors:  Elyahb A Kwizera; Mingrui Sun; Alisa M White; Jianrong Li; Xiaoming He
Journal:  ACS Biomater Sci Eng       Date:  2021-04-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.