Literature DB >> 2820538

Suture materials in contaminated wounds: a detailed comparison of a new suture with those currently in use.

S Paterson-Brown1, S Cheslyn-Curtis, J Biglin, J Dye, C S Easmon, H A Dudley.   

Abstract

The relationship between five different suture materials (expanded polytetrafluoroethylene (PTFE), polypropylene, polyglycolic acid, polydioxanone and polyglactin 910) and infection has been studied in 540 guinea-pig wounds contaminated with synergistic enteric organisms. The recently introduced expanded PTFE suture has been studied because, unlike the others, it has not previously been studied under these contaminated conditions. The incidence of wound infection in the control series was 26 per cent and all suture materials increased this figure significantly. The infection rate using expanded PTFE of 51 per cent was similar to all other sutures except polyglycolic acid, which produced an infection rate of 41 per cent. This difference was not statistically significant at the 5 per cent level. This confirms other studies including our own which show that the presence of most suture materials in contaminated wounds increases the incidence of infection. It further demonstrates that expanded PTFE is no different from other materials in this regard.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 2820538     DOI: 10.1002/bjs.1800740829

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  5 in total

1.  Surgipro mesh: not all multifilaments are the same.

Authors:  George T Rodeheaver
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-06

2.  Does Suture Type Influence Bacterial Retention and Biofilm Formation After Irrigation in a Mouse Model?

Authors:  David C Markel; Christopher Bergum; Bin Wu; Therese Bou-Akl; Weiping Ren
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

3.  Sutures for inguinal herniorrhaphy--a comparison of monofilaments with PTFE.

Authors:  J Cahill; A D Northeast; P E Jarret; R D Leach
Journal:  Ann R Coll Surg Engl       Date:  1989-03       Impact factor: 1.891

4.  A comparative study of polydioxanone (PDS) and polyglactin 910 (Vicryl) in colonic anastomoses in rats.

Authors:  E Andersen; K Søndenaa; J Holter
Journal:  Int J Colorectal Dis       Date:  1989-12       Impact factor: 2.571

5.  Pendant allyl crosslinking as a tunable shape memory actuator for vascular applications.

Authors:  Timothy C Boire; Mukesh K Gupta; Angela L Zachman; Sue Hyun Lee; Daniel A Balikov; Kwangho Kim; Leon M Bellan; Hak-Joon Sung
Journal:  Acta Biomater       Date:  2015-06-10       Impact factor: 8.947

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.