Literature DB >> 28204134

Evaluation of tricuspid valve regurgitation following laser lead extraction†.

Simon Pecha1, Liesa Castro1, Nils Gosau2, Matthias Linder1, Julia Vogler2, Stephan Willems2, Hermann Reichenspurner1, Samer Hakmi1.   

Abstract

OBJECTIVES: The objective of this study was to examine the effect of laser lead extraction (LLE) on the development of post-procedural tricuspid regurgitation (TR). Some reports have suggested an increase in TR associated with LLE. We present a series of patients who underwent both, LLE and complete echocardiographic evaluation for TR.
METHODS: A single centre analysis of consecutive patients referred for LLE between January 2012 and August 2015. One hundred and three patients had tricuspid valve function evaluated before the procedure with a transthoracic echocardiography (TTE), during the procedure using transoesophageal echocardiography and postoperatively using a TTE. TR was graded from 0 (none) to 4 (severe).
RESULTS: We treated 235 leads in 103 patients, including 118 ventricular leads. Seventy-seven were male (74.8%) and 26 female (25.2%), with a mean age of 65.6 ± 15.4 years. Mean time from initial lead implantation was 98.0 ± 67.3 months. Twenty-one patients (20.4%) had ejection fraction below 30%. No intra-procedural worsening of tricuspid valve function was seen with TEE in any of the patients. Ten patients (9.7%) were found to have TR before LLE that returned to normal valve function after the procedure. Two patients (1.9%) experienced mild TR after the procedure (both with tricuspid valve endocarditis). Ninety-one patients (88.3%) did not experience any significant change of the tricuspid valve function after LLE.
CONCLUSION: Transthoracic and transoesophageal echocardiography findings showed that laser lead extraction was not associated with a significant increase in the incidence of tricuspid valve regurgitation.
© The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  High frequency laser sheaths; ICD lead extraction; Laser lead extraction; Pacemaker lead extraction; Tricuspid regurgitation

Mesh:

Year:  2017        PMID: 28204134     DOI: 10.1093/ejcts/ezx011

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

1.  Differences in laser lead extraction of infected vs. non-infected leads.

Authors:  Simon Pecha; Liesa Castro; Julia Vogler; Matthias Linder; Nils Gosau; Stephan Willems; Hermann Reichenspurner; Samer Hakmi
Journal:  Heart Vessels       Date:  2018-04-05       Impact factor: 2.037

2.  Analysis of Risk Factors for Major Complications of 1500 Transvenous Lead Extraction Procedures with Especial Attention to Tricuspid Valve Damage.

Authors:  Łukasz Tułecki; Anna Polewczyk; Wojciech Jacheć; Dorota Nowosielecka; Konrad Tomków; Paweł Stefańczyk; Jarosław Kosior; Krzysztof Duda; Maciej Polewczyk; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2021-08-28       Impact factor: 3.390

3.  Tricuspid Valve Damage Related to Transvenous Lead Extraction.

Authors:  Anna Polewczyk; Wojciech Jacheć; Dorota Nowosielecka; Andrzej Tomaszewski; Wojciech Brzozowski; Dorota Szczęśniak-Stańczyk; Krzysztof Duda; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2022-09-27       Impact factor: 4.614

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.