Literature DB >> 28202324

Polarity and ion recombination corrections in continuous and pulsed beams for ionization chambers with high Z chamber walls.

Ghada Aldosary1, Habib Safigholi2, William Song2, Jan Seuntjens3, Arman Sarfehnia2.   

Abstract

In this work, the response of Farmer-type ionization chambers fitted with high atomic number (Z) walls is studied, and results of the effects of such walls on polarity and ion recombination correction factors in both continuous and pulsed beams are presented. Measurements were made in a continuous Co-60 beam and a pulsed 6MV linac beam using an Exradin-A12 ionization chamber fitted with the manufacturer's C-552 plastic wall, as well as geometrically identical walls made from aluminum, copper and molybdenum. The bias voltage was changed between 10values (range: +50 to +560V). Ion recombination was determined from Jaffé plots and by using the "two-voltage technique". The saturation charge measured with each chamber wall was extrapolated from Jaffé plots. Additionally, the effect of different wall materials on chamber response was studied using MCNP simulations. Results showed that the polarity correction factor is not significantly affected by changes in chamber wall material (within 0.1%). Furthermore, although the saturation charges greatly vary with each chamber wall material, and charge multiplication increases for higher atomic number wall materials, the standard methods of calculating ion recombination yielded results that differed by only 0.2%. Therefore, polarity and ion recombination correction factors are not greatly affected by the chamber wall material. The experimental saturation charges for all the different wall materials agreed well within the uncertainty with MCNP simulations. The breakdown of the linear relationship in Jaffé plots that was previously reported to exist for conventional chamber walls was also observed with the different wall materials.
Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Energy dependence; Ionization chamber walls; Jaffé plots; Polarity and ion recombination corrections

Mesh:

Substances:

Year:  2017        PMID: 28202324     DOI: 10.1016/j.ejmp.2017.01.019

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  1 in total

1.  The use of 0.5rcav as an effective point of measurement for cylindrical chambers may result in a systematic shift of electron percentage depth doses.

Authors:  Princess C Anusionwu; Jorge E Alpuche Aviles; Stephen Pistorius
Journal:  J Appl Clin Med Phys       Date:  2020-01-03       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.