Literature DB >> 28197988

In vivo and in vitro degradation comparison of pure Mg, Mg-10Gd and Mg-2Ag: a short term study.

I Marco1, A Myrissa, E Martinelli, F Feyerabend, R Willumeit-Römer, A M Weinberg, O Van der Biest.   

Abstract

The purpose of this study was to compare short term in vitro and in vivo biodegradation studies with low purity Mg (> 99.94 %), Mg-10Gd and Mg-2Ag designed for biodegradable implant applications. Three in vitro testing conditions were applied, using (i) phosphate buffered saline (PBS), (ii) Hank's balanced salt solution (HBSS) and (iii) Dulbecco's modified eagle medium (DMEM) in 5 % CO2 under sterile conditions. Gas evolution and mass loss (ML) were assessed, as well as the degradation layer, by elemental mapping and scanning electron microscopy (SEM). In vivo, implantations were performed on male Sprague-Dawley rats evaluating both, gas cavity volume and implant volume reduction by micro-computed tomography (µCT), 7 d after implantation. Samples were produced by casting, solution heat treatment and extrusion in disc and pin shape for the in vitro and in vivo experiments, respectively. Results showed that when the processing of the Mg sample varied, differences were found not only in the alloy impurity content and the grain size, but also in the corrosion behaviour. An increase of Fe and Ni or a large grain size seemed to play a major role in the degradation process, while the influence of alloying elements, such as Gd and Ag, played a secondary role. Results also indicated that cell culture conditions induced degradation rates and degradation layer elemental composition comparable to in vivo conditions. These in vitro and in vivo degradation layers consisted of Mg hydroxide, Mg-Ca carbonate and Ca phosphate.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28197988     DOI: 10.22203/eCM.v033a07

Source DB:  PubMed          Journal:  Eur Cell Mater        ISSN: 1473-2262            Impact factor:   3.942


  7 in total

1.  In Vitro Monitoring of Magnesium-Based Implants Degradation by Surface Analysis and Optical Spectroscopy.

Authors:  Hafiz Wajahat Hassan; Maryam Rahmati; Alejandro Barrantes; Håvard Jostein Haugen; Peyman Mirtaheri
Journal:  Int J Mol Sci       Date:  2022-05-29       Impact factor: 6.208

Review 2.  Bioresorbable Magnesium-Based Alloys as Novel Biomaterials in Oral Bone Regeneration: General Review and Clinical Perspectives.

Authors:  Valentin Herber; Begüm Okutan; Georgios Antonoglou; Nicole G Sommer; Michael Payer
Journal:  J Clin Med       Date:  2021-04-23       Impact factor: 4.241

3.  Influences of Extrusion and Silver Content on the Degradation of Mg-Ag Alloys In Vitro and In Vivo.

Authors:  Guanqi Liu; Jianmin Han; Xiaodong Yu; Shenpo Yuan; Zhihua Nie; Tiancheng Qiu; Ziyu Yan; Chengwen Tan; Chuanbin Guo
Journal:  Bioinorg Chem Appl       Date:  2022-04-23       Impact factor: 4.724

Review 4.  Updates on the research and development of absorbable metals for biomedical applications.

Authors:  Hendra Hermawan
Journal:  Prog Biomater       Date:  2018-05-22

5.  Biocompatibility Analyses of HF-Passivated Magnesium Screws for Guided Bone Regeneration (GBR).

Authors:  Ole Jung; Bernhard Hesse; Sanja Stojanovic; Christian Seim; Timm Weitkamp; Milijana Batinic; Oliver Goerke; Željka Perić Kačarević; Patrick Rider; Stevo Najman; Mike Barbeck
Journal:  Int J Mol Sci       Date:  2021-11-22       Impact factor: 5.923

6.  High-resolution ex vivo analysis of the degradation and osseointegration of Mg-xGd implant screws in 3D.

Authors:  Diana Krüger; Silvia Galli; Berit Zeller-Plumhoff; D C Florian Wieland; Niccolò Peruzzi; Björn Wiese; Philipp Heuser; Julian Moosmann; Ann Wennerberg; Regine Willumeit-Römer
Journal:  Bioact Mater       Date:  2021-11-14

Review 7.  Magnesium degradation under physiological conditions - Best practice.

Authors:  Jorge Gonzalez; Rui Qing Hou; Eshwara P S Nidadavolu; Regine Willumeit-Römer; Frank Feyerabend
Journal:  Bioact Mater       Date:  2018-02-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.