Literature DB >> 28194968

PEDOT(PSS) as Solid Contact for Ion-Selective Electrodes: The Influence of the PEDOT(PSS) Film Thickness on the Equilibration Times.

Marcin Guzinski1, Jennifer M Jarvis1, Felio Perez2, Bradford D Pendley1, Ernő Lindner1, Roland De Marco3,4,5, Gaston A Crespo6, Robert G Acres7, Raymart Walker3, Josiah Bishop3.   

Abstract

To understand the rate determining processes during the equilibration of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate-based (PEDOT(PSS)-based) solid contact (SC) ion-selective electrodes (ISEs), the surfaces of Pt, Au, and GC electrodes were coated with 0.1, 1.0, 2.0, and 4.0 μm thick galvanostatically deposited PEDOT(PSS) films. Next, potential vs time transients were recorded with these electrodes, with and without an additional potassium ion-selective membrane (ISM) coating, following their first contact with 0.1 M KCl solutions. The transients were significantly different when the multilayered sensor structures were assembled on Au or GC compared to Pt. The differences in the rate of equilibration were interpreted as a consequence of differences in the hydrophilicity of PEDOT(PSS) in contact with the substrate electrode surfaces based on X-ray photoelectron spectroscopy (XPS) and synchrotron radiation-XPS (SR-XPS) analysis of 10-100 nm thick PEDOT(PSS) films. The influence of the layer thickness of the electrochemically deposited PEDOT(PSS)-films on the hydrophilicity of these films has been documented by contact angle measurements over PEDOT(PSS)-coated Au, GC, and Pt electrode surfaces. This study demonstrates that it is possible to minimize the equilibration (conditioning) time of SC ISEs with aqueous solutions before usage by optimizing the thickness of the SC layer with a controlled ISM thickness. PEDOT(PSS)-coated Au and GC electrodes exhibit a significant negative potential drift during their equilibration in an aqueous solution. By coating the PEDOT(PSS) surface with an ISM, the negative potential drift is compensated by a positive potential drift related to the hydration of the ISM and activity changes at the PEDOT(PSS)|ISM interface. The potential drifts related to activity changes in the ISM have been determined by a novel adaptation of the "sandwich membrane" method.

Entities:  

Year:  2017        PMID: 28194968     DOI: 10.1021/acs.analchem.6b04625

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Hydrophobic laser-induced graphene potentiometric ion-selective electrodes for nitrate sensing.

Authors:  Robert G Hjort; Raquel R A Soares; Jingzhe Li; Dapeng Jing; Lindsey Hartfiel; Bolin Chen; Bryan Van Belle; Michelle Soupir; Emily Smith; Eric McLamore; Jonathan C Claussen; Carmen L Gomes
Journal:  Mikrochim Acta       Date:  2022-02-26       Impact factor: 5.833

2.  A New Composite Structure of PEDOT/PSS: Macro-Separated Layers by a Polyelectrolyte Brush.

Authors:  Keita Yasumoro; Yushi Fujita; Hideki Arimatsu; Takuya Fujima
Journal:  Polymers (Basel)       Date:  2020-02-16       Impact factor: 4.329

3.  Comparison of Different Commercial Conducting Materials as Ion-to-Electron Transducer Layers in Low-Cost Selective Solid-Contact Electrodes.

Authors:  C Ocaña; M Muñoz-Correas; N Abramova; A Bratov
Journal:  Sensors (Basel)       Date:  2020-02-29       Impact factor: 3.576

4.  Stretchable Sweat-Activated Battery in Skin-Integrated Electronics for Continuous Wireless Sweat Monitoring.

Authors:  Yiming Liu; Xingcan Huang; Jingkun Zhou; Chun Ki Yiu; Zhen Song; Wei Huang; Sina Khazaee Nejad; Hu Li; Tsz Hung Wong; Kuanming Yao; Ling Zhao; Woojung Yoo; Wooyoung Park; Jiyu Li; Ya Huang; Hiuwai Raymond Lam; Enming Song; Xu Guo; Yanwei Wang; Zhenxue Dai; Lingqian Chang; Wen Jung Li; Zhaoqian Xie; Xinge Yu
Journal:  Adv Sci (Weinh)       Date:  2022-01-28       Impact factor: 16.806

5.  TEMPO-Functionalized Carbon Nanotubes for Solid-Contact Ion-Selective Electrodes with Largely Improved Potential Reproducibility and Stability.

Authors:  József Kozma; Soma Papp; Róbert E Gyurcsányi
Journal:  Anal Chem       Date:  2022-05-27       Impact factor: 8.008

6.  Carbon-Based Transducers for Solid-Contact Calcium Ion-Selective Electrodes: Mesopore and Nitrogen-Doping Effects.

Authors:  Yirong Zhang; Yitian Tang; Rongfeng Liang; Lijie Zhong; Jiexian Xu; Huici Lu; Xiaofeng Xu; Tingting Han; Yu Bao; Yingming Ma; Shiyu Gan; Li Niu
Journal:  Membranes (Basel)       Date:  2022-09-19
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.