Literature DB >> 28193075

Uric Acid Monitoring with a Smartphone as the Electrochemical Analyzer.

Jinhong Guo1,2.   

Abstract

We report the world's first medical smartphone as an electrochemical analyzer, which is incorporated with an enzymatic test strip for rapid characterization of UA (uric acid) in peripheral whole blood. A disposable electrochemical uric acid test strip was connected to the electrochemical module integrated with the smartphone through a specific interface, a slot around the edge of smartphone. A 3 μL human finger whole blood drop is applied on the strip for UA evaluation and compared to the clinical biochemical analyzer with satisfactory agreement. The measured data was saved and uploaded into a personal health management center through the mobile Internet.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 28193075     DOI: 10.1021/acs.analchem.6b04345

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

1.  Measurement of serum phosphate levels using a mobile sensor.

Authors:  Aniruddha Ray; Sarah Esparza; Dimei Wu; Mark R Hanudel; Hyou-Arm Joung; Barbara Gales; Derek Tseng; Isidro B Salusky; Aydogan Ozcan
Journal:  Analyst       Date:  2020-03-02       Impact factor: 4.616

2.  Frequency Modulated Parametric Oscillation for Antenna Powered Wireless Transmission of Voltage Sensing Signals.

Authors:  Wei Qian; Chunqi Qian
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-11-05       Impact factor: 3.833

3.  β-Cyclodextrin functionalized 3D reduced graphene oxide composite-based electrochemical sensor for the sensitive detection of dopamine.

Authors:  Xuan Chen; Na Li; Yanqin Rong; Yuli Hou; Yu Huang; Wenting Liang
Journal:  RSC Adv       Date:  2021-08-19       Impact factor: 4.036

4.  A Numerical Model of Blood Flow Velocity Measurement Based on Finger Ring.

Authors:  Fu Yusheng; Qiyu Wang; Jianbo Yi; Dan Song; Xin Xiang
Journal:  J Healthc Eng       Date:  2018-10-03       Impact factor: 2.682

5.  Point-of-Care Quantification of Serum Alpha-Fetoprotein for Screening Birth Defects in Resource-Limited Settings: Proof-of-Concept Study.

Authors:  Balaji Srinivasan; Julia L Finkelstein; David Erickson; Saurabh Mehta
Journal:  JMIR Biomed Eng       Date:  2020-08-14

6.  Electrochemical Sensor Nanoarchitectonics for Sensitive Detection of Uric Acid in Human Whole Blood Based on Screen-Printed Carbon Electrode Equipped with Vertically-Ordered Mesoporous Silica-Nanochannel Film.

Authors:  Kai Ma; Luoxing Yang; Jun Liu; Jiyang Liu
Journal:  Nanomaterials (Basel)       Date:  2022-03-31       Impact factor: 5.076

7.  Development of micropillar array electrodes for highly sensitive detection of biomarkers.

Authors:  Chaozhan Chen; Bin Ran; Zhenxing Wang; Hongli Zhao; Minbo Lan; Huaying Chen; Yonggang Zhu
Journal:  RSC Adv       Date:  2020-11-10       Impact factor: 4.036

8.  A Novel Turn-On Fluorescence Probe Based on Cu(II) Functionalized Metal-Organic Frameworks for Visual Detection of Uric Acid.

Authors:  Jie Yang; Jie Che; Xin Jiang; Yangchun Fan; Daojiang Gao; Jian Bi; Zhanglei Ning
Journal:  Molecules       Date:  2022-07-27       Impact factor: 4.927

9.  Sub-nanoliter, real-time flow monitoring in microfluidic chips using a portable device and smartphone.

Authors:  Yuksel Temiz; Emmanuel Delamarche
Journal:  Sci Rep       Date:  2018-07-13       Impact factor: 4.379

Review 10.  Smartphone-Based Biosensor Devices for Healthcare: Technologies, Trends, and Adoption by End-Users.

Authors:  Rossana E Madrid; Fernando Ashur Ramallo; Daniela E Barraza; Roberto E Chaile
Journal:  Bioengineering (Basel)       Date:  2022-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.