| Literature DB >> 28192998 |
Andrew Joseph Novic1, Dominique S O'Brien2, Sarit L Kaserzon1, Darryl W Hawker3, Stephen E Lewis2, Jochen F Mueller1.
Abstract
The suitability of passive samplers (Chemcatcher) as an alternative to grab sampling in estimating time-weighted average (TWA) concentrations and total loads of herbicides was assessed. Grab sampling complemented deployments of passive samplers in a tropical waterway in Queensland, Australia, before, during and after a flood event. Good agreement was observed between the two sampling modes in estimating TWA concentrations that was independent of herbicide concentrations ranging over 2 orders of magnitude. In a flood-specific deployment, passive sampler TWA concentrations underestimated mean grab sampler (n = 258) derived concentrations of atrazine, diuron, ametryn, and metolachlor by an average factor of 1.29. No clear trends were evident in the ratios of load estimates from passive samplers relative to grab samples that ranged between 0.3 and 1.8 for these analytes because of the limitations of using TWA concentrations to derive flow-weighted loads. Stratification of deployments by flow however generally resulted in noticeable improvements in passive sampler load estimates. By considering the magnitude of the uncertainty (interquartile range and the root-mean-squared error) of load estimates a modeling exercise showed that passive samplers were a viable alternative to grab sampling since between 3 and 17 grab samples were needed before grab sampling results had less uncertainty.Entities:
Mesh:
Substances:
Year: 2017 PMID: 28192998 DOI: 10.1021/acs.est.6b02858
Source DB: PubMed Journal: Environ Sci Technol ISSN: 0013-936X Impact factor: 9.028