Advantage of Eu3+ -Doped Polystyrene Microspheres Compared with Colloidal Gold Used in Immunochromatographic Assays for the Detection of Melamine in Milk.

Yiwei Tang1, Hong Zhang1, Xiuying Liu1, Evan Trofimchuk2, Shaolong Feng2, Tao Ma1, Xue Gao1, Shubing Fang1, Xiaonan Lu2.   

Abstract

Colloidal gold and Eu3+ -doped fluorescent microspheres were applied as labels to develop the immunochromatographic strips for detecting melamine in milk. Under the optimized condition, the visual detection limit of colloidal gold-immunochromatographic test strip (ICTS) was 150 μg/L of melamine in phosphate-buffered saline (PBS), although the visual detection limit of fluorescent nanoparticles (FN)-ICTS was 75 μg/L in PBS. As thermal acceleration test, FN-ICTS could be stored at 37 °C for at least 11 d before sample testing, but the color of the lines on colloidal gold-ICTS faded away after 7-d storage. The visual result of FN-ICTS was more stable than that of colloidal gold-ICTS, and the fluorescence intensity of the line on FN-ICTS could be maintained up to 30 d at 22 °C after sample testing. Once the immunochromatographic strips were used to detect melamine in milk, no negative effect of milk components on the performance of FN-ICTS was identified, whereas the performance of colloidal gold-ICTS was significantly influenced by milk matrix.
© 2017 Institute of Food Technologists®.

Entities:  

Keywords:  dairy products; food safety; immunochromatographic strip; rapid detection

Mesh:

Substances:

Year:  2017        PMID: 28192612     DOI: 10.1111/1750-3841.13654

Source DB:  PubMed          Journal:  J Food Sci        ISSN: 0022-1147            Impact factor:   3.167


  3 in total

1.  Fluorometric determination of ciprofloxacin using molecularly imprinted polymer and polystyrene microparticles doped with europium(III)(DBM)3phen.

Authors:  Zhuanying Li; Zhimeng Cui; Yiwei Tang; Xiuying Liu; Xuemei Zhang; Bingxiang Liu; Xianghong Wang; Mohamed Shehata Draz; Xue Gao
Journal:  Mikrochim Acta       Date:  2019-05-07       Impact factor: 5.833

2.  Comparison of the detection performance of two different one-step-combined test strips with fluorescent microspheres or colored microspheres as tracers for influenza A and B viruses.

Authors:  Qingjun Pan; Weiquan Wu; Shuzhen Liao; Sijie Wang; Chunfei Zhao; Chen Li; Ping Wu
Journal:  Virol J       Date:  2019-07-19       Impact factor: 4.099

3.  Automatic Range Adjustment of the Fluorescence Immunochromatographic Assay Based on Image Processing.

Authors:  Ruixin Jiang; Huihuang Wu; Jianpeng Yang; Haiyan Jiang; Min Du; Mangi Vai; Siohang Pun; Yueming Gao
Journal:  Sensors (Basel)       Date:  2019-12-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.