Literature DB >> 28191682

Aortic root thrombus complicated by left main coronary artery occlusion visualized by 3D echocardiography in a patient with continuous-flow left ventricular assist device.

Monique S Tanna1, Alex Reyentovich1, Leora B Balsam2, John A Dodson1, Alan F Vainrib1, Ricardo J Benenstein1, Barry P Rosenzweig1, Muhamed Saric1.   

Abstract

Aortic root thrombus is an uncommon complication of continuous-flow left ventricular assist devices (LVAD). We present the case of a 71-year-old man with ischemic cardiomyopathy who underwent destination therapy HeartMate II LVAD placement. Eighteen months later, he presented with a cerebrovascular accident followed by myocardial infarction. Transesophageal echocardiography revealed an aortic root thrombus spanning the left and noncoronary cusps and obliterating the left main coronary artery. We discuss the incidence, risk factors, and management of aortic root thrombus in LVAD patients. To our knowledge, this is the first report of three-dimensional echocardiography used to characterize an LVAD-associated aortic root thrombus.
© 2017, Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic root thrombus; coronary artery occlusion; left ventricular assist device; three-dimensional transesophageal echocardiography

Mesh:

Year:  2017        PMID: 28191682     DOI: 10.1111/echo.13425

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

1.  When Ablation Is Not the Answer: Acute Left Main Thrombosis Causing Incessant Ventricular Tachycardia Following Left Ventricular Assist Device Implant.

Authors:  Mohammad K Mojadidi; Ahmed N Mahmoud; Akram Y Elgendy; R David Anderson
Journal:  Cureus       Date:  2017-10-21

2.  Case Report: Two Cases of Watershed Phenomenon in Mechanical Circulatory Support Devices: Computed Tomography Angiography Imaging and Literature Review.

Authors:  Guiying Du; Jiwang Zhang; Junbo Liu; Lijuan Fan
Journal:  Front Cardiovasc Med       Date:  2022-05-13

3.  Aortic Valve Thrombosis after Valve-Sparing Aortic Root Replacement and Insertion of an Extracorporeal Left Ventricular Assist Device, Masked by Mediastinal Packing.

Authors:  Yoshiaki Uda; Leonid Minkovich; Maral Ouzounian; Massimiliano Meineri
Journal:  J Cardiovasc Echogr       Date:  2018 Jul-Sep
  3 in total