Literature DB >> 28190699

Correcting false positive medium-chain acyl-CoA dehydrogenase deficiency results from newborn screening; synthesis, purification, and standardization of branched-chain C8 acylcarnitines for use in their selective and accurate absolute quantitation by UHPLC-MS/MS.

Paul E Minkler1, Maria S K Stoll1, Stephen T Ingalls1, Charles L Hoppel2.   

Abstract

While selectively quantifying acylcarnitines in thousands of patient samples using UHPLC-MS/MS, we have occasionally observed unidentified branched-chain C8 acylcarnitines. Such observations are not possible using tandem MS methods, which generate pseudo-quantitative acylcarnitine "profiles". Since these "profiles" select for mass alone, they cannot distinguish authentic signal from isobaric and isomeric interferences. For example, some of the samples containing branched-chain C8 acylcarnitines were, in fact, expanded newborn screening false positive "profiles" for medium-chain acyl-CoA dehydrogenase deficiency (MCADD). Using our fast, highly selective, and quantitatively accurate UHPLC-MS/MS acylcarnitine determination method, we corrected the false positive tandem MS results and reported the sample results as normal for octanoylcarnitine (the marker for MCADD). From instances such as these, we decided to further investigate the presence of branched-chain C8 acylcarnitines in patient samples. To accomplish this, we synthesized and chromatographically characterized several branched-chain C8 acylcarnitines (in addition to valproylcarnitine): 2-methylheptanoylcarnitine, 6-methylheptanoylcarnitine, 2,2-dimethylhexanoylcarnitine, 3,3-dimethylhexanoylcarnitine, 3,5-dimethylhexanoylcarnitine, 2-ethylhexanoylcarnitine, and 2,4,4-trimethylpentanoylcarnitine. We then compared their behavior with branched-chain C8 acylcarnitines observed in patient samples and demonstrated our ability to chromographically resolve, and thus distinguish, octanoylcarnitine from branched-chain C8 acylcarnitines, correcting false positive MCADD results from expanded newborn screening.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Acylcarnitine; False positive; Medium-chain acyl-CoA dehydrogenase deficiency (MCADD); Newborn screening; Valproate; Valproylcarnitine

Mesh:

Substances:

Year:  2017        PMID: 28190699     DOI: 10.1016/j.ymgme.2017.02.006

Source DB:  PubMed          Journal:  Mol Genet Metab        ISSN: 1096-7192            Impact factor:   4.797


  2 in total

1.  Mass Spectral Library of Acylcarnitines Derived from Human Urine.

Authors:  Xinjian Yan; Sanford P Markey; Ramesh Marupaka; Qian Dong; Brian T Cooper; Yuri A Mirokhin; William E Wallace; Stephen E Stein
Journal:  Anal Chem       Date:  2020-04-23       Impact factor: 6.986

2.  Laboratory analysis of acylcarnitines, 2020 update: a technical standard of the American College of Medical Genetics and Genomics (ACMG).

Authors:  Marcus J Miller; Kristina Cusmano-Ozog; Devin Oglesbee; Sarah Young
Journal:  Genet Med       Date:  2020-10-19       Impact factor: 8.822

  2 in total