Literature DB >> 28185373

Dual Anchor Internal Pulse Generator Technique May Lower Risk of Twiddler's Syndrome: A Case Series and Literature Review.

Michał Roman Sobstyl1, Mirosław Ząbek1, Grażyna Brzuszkiewicz-Kuźmicka2, Tomasz Pasterski1.   

Abstract

BACKGROUND: Twiddler's syndrome (TS) is described as a spontaneous rotation or intentional external manipulation of implanted internal pulse generator (IPG) for neurological or cardiac disorders. There have been identified some predisposing factors of the development of TS such as: loose subcutaneous tissue, older age of individuals undergoing deep brain stimulation (DBS) procedures, creation of too large pockets for IPG. Apart from these factors, the construction of IPG itself may predispose to the development of TS.
OBJECTIVE: To report the clinical course of three patients with TS. Moreover, the purpose of this study is to present the change in fixation technique of IPG that can prevent the occurrence of TS in patients after DBS procedure.
METHODS: A prospectively collected database of all hardware related complications for patients operated on for various movement disorders was analyzed. In a total number of 347 DBS systems implanted since 1999 we have identified three patients diagnosed with TS. All three patients with TS in our series were implanted with the IPG harboring a single anchoring hole. This complication has never occurred in patients with the IPG harboring two anchoring holes in our center.
RESULTS: All three patients underwent revision surgery. During reoperations all connection cables were replaced and IPG sutured with one additional silk stich through the plastic housing to immobilize it properly in subcutaneous pocket. There were no recurrences of TS in our patients.
CONCLUSIONS: Our case series suggests that a predisposing factor of TS may also be the construction of IPG itself (a single anchoring hole intended for fixation), which naturally represents less fixation of the IPG to the fascia or muscle in the subcutaneous pocket. In this preliminary report we present suggestions to lower the risk of TS, including using dual anchor capable IPGs, reducing pocket volume and using nonabsorbable suture.
© 2017 International Neuromodulation Society.

Entities:  

Keywords:  Deep brain stimulation; Parkinson's disease; Twiddler's syndrome; dyskinesia; hardware failure; tremor

Mesh:

Year:  2017        PMID: 28185373     DOI: 10.1111/ner.12581

Source DB:  PubMed          Journal:  Neuromodulation        ISSN: 1094-7159


  7 in total

Review 1.  A systematic review of Twiddler's syndrome: a hardware-related complication of deep brain stimulation.

Authors:  Xiaowei Liu; Yangyang Xu; Hagai Bergman; Siyu Li; Wei Wang
Journal:  Neurosurg Rev       Date:  2021-09-07       Impact factor: 3.042

2.  Erosive Twiddler's Syndrome: A Severe Case with Externalization of the Pacemaker.

Authors:  Ryan Stuart; Zachary Gilbert; Damian N Valencia
Journal:  Cureus       Date:  2020-03-29

3.  Twiddler's syndrome with a subcutaneous implantable cardioverter-defibrillator presenting with an inappropriate shock: a case report.

Authors:  C Fielder Camm; Kim Rajappan; Mark Curson; Lindsey Tilling
Journal:  Eur Heart J Case Rep       Date:  2019-11-07

4.  Complications After Deep Brain Stimulation: A 21-Year Experience in 426 Patients.

Authors:  In-Ho Jung; Kyung Won Chang; So Hee Park; Won Seok Chang; Hyun Ho Jung; Jin Woo Chang
Journal:  Front Aging Neurosci       Date:  2022-04-07       Impact factor: 5.702

5.  A case of twiddler's syndrome with a subcutaneous implantable cardioverter-defibrillator.

Authors:  Chengyue Jin; Sei Iwai; Jason Jacobson; Aileen Ferrick
Journal:  HeartRhythm Case Rep       Date:  2022-08-15

6.  Delayed presentation of pacemaker Reel Syndrome and lead damage: Coincidence or consequence?

Authors:  Safae Hilal; Fatima Chikhi; Fadoum Hassan; Ibtissam Fellat; Mohammed Cherti
Journal:  Indian Pacing Electrophysiol J       Date:  2022-07-09

7.  Twiddler's syndrome: Between mechanical recoil and behavioral troubles.

Authors:  Mohamed El Minaoui; Wassim Beladel
Journal:  Radiol Case Rep       Date:  2022-08-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.