Literature DB >> 28182580

Internal dosimetry with the Monte Carlo code GATE: validation using the ICRP/ICRU female reference computational model.

Daphnée Villoing1, Sara Marcatili, Marie-Paule Garcia, Manuel Bardiès.   

Abstract

The purpose of this work was to validate GATE-based clinical scale absorbed dose calculations in nuclear medicine dosimetry. GATE (version 6.2) and MCNPX (version 2.7.a) were used to derive dosimetric parameters (absorbed fractions, specific absorbed fractions and S-values) for the reference female computational model proposed by the International Commission on Radiological Protection in ICRP report 110. Monoenergetic photons and electrons (from 50 keV to 2 MeV) and four isotopes currently used in nuclear medicine (fluorine-18, lutetium-177, iodine-131 and yttrium-90) were investigated. Absorbed fractions, specific absorbed fractions and S-values were generated with GATE and MCNPX for 12 regions of interest in the ICRP 110 female computational model, thereby leading to 144 source/target pair configurations. Relative differences between GATE and MCNPX obtained in specific configurations (self-irradiation or cross-irradiation) are presented. Relative differences in absorbed fractions, specific absorbed fractions or S-values are below 10%, and in most cases less than 5%. Dosimetric results generated with GATE for the 12 volumes of interest are available as supplemental data. GATE can be safely used for radiopharmaceutical dosimetry at the clinical scale. This makes GATE a viable option for Monte Carlo modelling of both imaging and absorbed dose in nuclear medicine.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28182580     DOI: 10.1088/1361-6560/62/5/1885

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Pre- and post-treatment image-based dosimetry in90Y-microsphere radioembolization using the TOPAS Monte Carlo toolkit.

Authors:  Alejandro Bertolet; Eric Wehrenberg-Klee; Mislav Bobić; Clemens Grassberger; Joseph Perl; Harald Paganetti; Jan Schuemann
Journal:  Phys Med Biol       Date:  2021-12-29       Impact factor: 3.609

2.  Estimated Organ Doses to Patients from Diagnostic Nuclear Medicine Examinations over Five Decades: 1960-2010.

Authors:  Daphnée Villoing; Vladimir Drozdovitch; Steven L Simon; Cari M Kitahara; Martha S Linet; Dunstana R Melo
Journal:  Health Phys       Date:  2017-12       Impact factor: 1.316

3.  BIGDOSE: software for 3D personalized targeted radionuclide therapy dosimetry.

Authors:  Tiantian Li; Licheng Zhu; Zhonglin Lu; Na Song; Ko-Han Lin; Greta S P Mok
Journal:  Quant Imaging Med Surg       Date:  2020-01

4.  Quantification of internal dosimetry in PET patients II: Individualized Monte Carlo-based dosimetry for [18F]fluorocholine PET.

Authors:  Sara Neira; Jacobo Guiu-Souto; Paulino Pais; Sofía Rodríguez Martínez de Llano; Carlos Fernández; Virginia Pubul; Álvaro Ruibal; Miguel Pombar; Araceli Gago-Arias; Juan Pardo-Montero
Journal:  Med Phys       Date:  2021-07-29       Impact factor: 4.506

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.