Literature DB >> 28182554

Weight Multispectral Reconstruction Strategy for Enhanced Reconstruction Accuracy and Stability With Cerenkov Luminescence Tomography.

.   

Abstract

Cerenkov luminescence tomography (CLT) provides a novel technique for 3-D noninvasive detection of radiopharmaceuticals in living subjects. However, because of the severe scattering of Cerenkov light, the reconstruction accuracy and stability of CLT is still unsatisfied. In this paper, a modified weight multispectral CLT (wmCLT) reconstruction strategy was developed which split the Cerenkov radiation spectrum into several sub-spectral bands and weighted the sub-spectral results to obtain the final result. To better evaluate the property of the wmCLT reconstruction strategy in terms of accuracy, stability and practicability, several numerical simulation experiments and in vivo experiments were conducted and the results obtained were compared with the traditional multispectral CLT (mCLT) and hybrid-spectral CLT (hCLT) reconstruction strategies. The numerical simulation results indicated that wmCLT strategy significantly improved the accuracy of Cerenkov source localization and intensity quantitation and exhibited good stability in suppressing noise in numerical simulation experiments. And the comparison of the results achieved from different in vivo experiments further indicated significant improvement of the wmCLT strategy in terms of the shape recovery of the bladder and the spatial resolution of imaging xenograft tumors. Overall the strategy reported here will facilitate the development of nuclear and optical molecular tomography in theoretical study.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28182554     DOI: 10.1109/TMI.2017.2658661

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  Attention mechanism-based locally connected network for accurate and stable reconstruction in Cerenkov luminescence tomography.

Authors:  Xiaoning Zhang; Meishan Cai; Lishuang Guo; Zeyu Zhang; Biluo Shen; Xiaojun Zhang; Zhenhua Hu; Jie Tian
Journal:  Biomed Opt Express       Date:  2021-11-18       Impact factor: 3.732

2.  L1-L2 norm regularization via forward-backward splitting for fluorescence molecular tomography.

Authors:  Heng Zhang; Xiaowei He; Jingjing Yu; Xuelei He; Hongbo Guo; Yuqing Hou
Journal:  Biomed Opt Express       Date:  2021-11-29       Impact factor: 3.732

Review 3.  Dual-Mode Tumor Imaging Using Probes That Are Responsive to Hypoxia-Induced Pathological Conditions.

Authors:  S A Amali S Subasinghe; Robia G Pautler; Md Abul Hassan Samee; Jason T Yustein; Matthew J Allen
Journal:  Biosensors (Basel)       Date:  2022-06-30

4.  Noninvasive multimodal fluorescence and magnetic resonance imaging of whole-organ intervertebral discs.

Authors:  Wuwei Ren; Shangbin Cui; Mauro Alini; Sibylle Grad; Quanyu Zhou; Zhen Li; Daniel Razansky
Journal:  Biomed Opt Express       Date:  2021-05-07       Impact factor: 3.732

Review 5.  Recent methodology advances in fluorescence molecular tomography.

Authors:  Yu An; Kun Wang; Jie Tian
Journal:  Vis Comput Ind Biomed Art       Date:  2018-09-05

6.  Real-time intraoperative glioma diagnosis using fluorescence imaging and deep convolutional neural networks.

Authors:  Biluo Shen; Zhe Zhang; Xiaojing Shi; Caiguang Cao; Zeyu Zhang; Zhenhua Hu; Nan Ji; Jie Tian
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-04-27       Impact factor: 9.236

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.