Literature DB >> 28182361

Evaluation of Line Immunoassay to Detect HTLV-1 Infection in an Endemic Area, Southwestern Japan; Comparison with Polymerase Chain Reaction and Western Blot.

Kazumi Umeki, Kunihiko Umekita, Yuuki Hashikura, Ikuo Yamamoto, Kazuyoshi Kubo, Yasuhiro Nagatomo, Akihiko Okayama.   

Abstract

BACKGROUND: Human T-lymphotropic virus type 1 (HTLV-1) has been recognized as a cause of adult T-cell leukemia/lymphoma, HTLV-1-associated myelopathy/tropical spastic paraparesis, and HTLV-1-associated uveitis. HTLV-1 infection is normally detected by screening for HTLV-1 antibodies, and positive samples are confirmed by Western blot (WB). However, WB fails to confirm some samples that were positive for HTLV-1 antibodies on screening. Line immunoassay (LIA) is commonly used in Europe and Brazil, but not in Japan. Therefore, we evaluated the performance of LIA as a method of confirming HTLV-1 antibodies using samples in Japan.
METHODS: LIA was compared with polymerase chain reaction (PCR) and WB using 50 negative and 70 positive samples tested by chemiluminescent enzyme immunoassay (CLEIA) in Miyazaki, Japan, an HTLV-1 endemic area. LIA (INNO-LIA HTLVI/II Score) and WB (Problot HTLV-I) were performed according to the manufacturer's instructions. Real-time PCR for HTLV-1 pX region was performed using DNA derived from white blood cells. The samples that tested negative by real-time PCR were further tested by nested PCR.
RESULTS: All 50 CLEIA negative samples were determined to be negative by LIA and PCR. Of the 70 positive samples, 66 tested positive by both of LIA and PCR. Three samples tested negative by LIA and PCR, and the remaining sample (PCR negative) showed non-specific staining in LIA and WB. WB showed more indeterminate results than LIA. Gp21 antibody in LIA demonstrated a high ability to discriminate between positive and negative PCR results. Furthermore, the degree of gp21 antibody reaction by LIA showed correlation with HTLV-1 proviral loads (PVLs).
CONCLUSIONS: Our results indicate that LIA performs well in confirming HTLV-1 seropositivity by showing a low incidence of indeterminate results and good agreement with PCR using samples in Japan, although the number of samples tested was small. In addition, semi-quantitative antibody titer to gp21 correlated well with HTLV-1 PVLs. Further study including larger samples is necessary to determine the positioning of LIA for HTLV-1 detection in Japan.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28182361     DOI: 10.7754/Clin.Lab.2016.160501

Source DB:  PubMed          Journal:  Clin Lab        ISSN: 1433-6510            Impact factor:   1.138


  9 in total

1.  Infection of defective human T-lymphotropic virus type 1.

Authors:  Yuuki Hashikura; Kazumi Umeki; Kunihiko Umekita; Hajime Nomura; Akiteru Yamada; Ikuo Yamamoto; Hiroo Hasegawa; Katsunori Yanagihara; Akihiko Okayama
Journal:  Hum Cell       Date:  2017-01-09       Impact factor: 4.174

Review 2.  HTLV-1: A real pathogen or a runaway guest of a diseased cell?

Authors:  L I B Kanzaki
Journal:  J Biosci       Date:  2018-09       Impact factor: 1.826

3.  Molecular detection of human T-lymphotropic virus type 1 infection among oncology patients in Germany: A retrospective view.

Authors:  Matias Ruggieri; Carolina Berini; Nicolas Ducasa; Miroslav Malkovsky; Paul Fisch; Mirna Biglione
Journal:  PLoS One       Date:  2019-05-28       Impact factor: 3.240

4.  Screening for retroviruses and hepatitis viruses using dried blood spots reveals a high prevalence of occult hepatitis B in Ghana.

Authors:  Carmen de Mendoza; José M Bautista; Susana Pérez-Benavente; Roger Kwawu; Julius Fobil; Vicente Soriano; Amalia Díez
Journal:  Ther Adv Infect Dis       Date:  2019-05-23

Review 5.  A Nationwide Antenatal Human T-Cell Leukemia Virus Type-1 Antibody Screening in Japan.

Authors:  Kazuo Itabashi; Tokuo Miyazawa; Akihiko Sekizawa; Akifumi Tokita; Shigeru Saito; Hiroyuki Moriuchi; Yasuhito Nerome; Kaoru Uchimaru; Toshiki Watanabe
Journal:  Front Microbiol       Date:  2020-04-09       Impact factor: 5.640

6.  Specificity of HTLV screening tests and its impact on health care program costs: The perspective of antenatal screening in Brazil.

Authors:  Carolina Rosadas; Adele Caterino-de-Araujo; Graham Philip Taylor
Journal:  Rev Soc Bras Med Trop       Date:  2021-03-08       Impact factor: 1.581

7.  Brazilian Protocol for Sexually Transmitted Infections 2020: human T-cell lymphotropic virus (HTLV) infection.

Authors:  Carolina Rosadas; Carlos Brites; Denise Arakaki-Sanchez; Jorge Casseb; Ricardo Ishak
Journal:  Rev Soc Bras Med Trop       Date:  2021-05-17       Impact factor: 1.581

Review 8.  Blocking HTLV-1/2 silent transmission in Brazil: Current public health policies and proposal for additional strategies.

Authors:  Carolina Rosadas; Maria Luiza B Menezes; Bernardo Galvão-Castro; Tatiane Assone; Angélica E Miranda; Mayra G Aragón; Adele Caterino-de-Araujo; Graham P Taylor; Ricardo Ishak
Journal:  PLoS Negl Trop Dis       Date:  2021-09-23

9.  Establishment of a novel diagnostic test algorithm for human T-cell leukemia virus type 1 infection with line immunoassay replacement of western blotting: a collaborative study for performance evaluation of diagnostic assays in Japan.

Authors:  Kazu Okuma; Madoka Kuramitsu; Toshihiro Niwa; Tomokuni Taniguchi; Yumiko Masaki; Gohzoh Ueda; Chieko Matsumoto; Rieko Sobata; Yasuko Sagara; Hitomi Nakamura; Masahiro Satake; Kiyonori Miura; Naoki Fuchi; Hideaki Masuzaki; Akihiko Okayama; Kazumi Umeki; Yoshihisa Yamano; Tomoo Sato; Masako Iwanaga; Kaoru Uchimaru; Makoto Nakashima; Atae Utsunomiya; Ryuji Kubota; Kenji Ishitsuka; Hiroo Hasegawa; Daisuke Sasaki; Ki-Ryang Koh; Mai Taki; Kisato Nosaka; Masao Ogata; Isao Naruse; Noriaki Kaneko; Sara Okajima; Kenta Tezuka; Emi Ikebe; Sahoko Matsuoka; Kazuo Itabashi; Shigeru Saito; Toshiki Watanabe; Isao Hamaguchi
Journal:  Retrovirology       Date:  2020-08-24       Impact factor: 4.602

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.