Literature DB >> 28180192

Shear wave elastography imaging for detecting malignant lesions of the liver: a systematic review and pooled meta-analysis.

Yang Jiao1, Fajin Dong1, Hui Wang2, Lei Zhang1, Jinfeng Xu1, Jing Zheng1, Haibo Fan2, Hanjing Gan1, Lixin Chen1, Min Li3.   

Abstract

AIM: To investigate the clinical utility of shear wave elastography (SWE) imaging in the identification of malignant and benign lesions of the liver lesions by conducting a meta-analysis.
MATERIAL AND METHODS: The Cochrane library, Embase and Pubmed were searched for relevant studies with publication data through February 2016. Studies evaluating the diagnostic accuracy of SWE in the identification of malignant and benign lesions of the liver using SWE technology were selected. The cytology, histology or clinical imaging was used as the reference standard. The pooled sensitivity, specificity, diagnostic odds ratio, likelihood ratio, and the area under hierarchical summary receiver operating characteristic curve (HSROC) were used to examine the diagnostic accuracy.
RESULTS: A total of 9 cohort studies involving 1046 liver lesions (malignant 679) from 968 patients were identified. All of the 9 studies were prospective studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio of SWE in differentiating malignant and benign liver lesions were 82.2% (95% CI: 73.4-88.5), 80.2% (95% CI: 73.3-85.7), 4.159 (95% CI: 2.899-5.966), 0.222 (95% CI: 0.140-0.352), and 18.749 (95% CI: 8.746-40.195), respectively. The area under the HSROC curve was 87% (95% CI: 84-90).
CONCLUSIONS: This meta-analysis indicates that SWE is useful in evaluating the stiffness of liver lesions and in differentiating between malignant and benign lesions. Due to the high sensitivity, specificity, and diagnostic odds ratio, SWE can be considered as a useful complement to conventional ultrasonography.

Entities:  

Mesh:

Year:  2017        PMID: 28180192     DOI: 10.11152/mu-925

Source DB:  PubMed          Journal:  Med Ultrason        ISSN: 1844-4172            Impact factor:   1.611


  5 in total

1.  Correlation between acoustic radiation force impulse (ARFI)-based tissue elasticity measurements and perfusion parameters acquired by perfusion CT in cirrhotic livers: a proof of principle.

Authors:  Michael Esser; Michael Bitzer; Manuel Kolb; Jan Fritz; Mustafa Kurucay; Christer Ruff; Marius Horger
Journal:  J Med Ultrason (2001)       Date:  2018-06-13       Impact factor: 1.314

2.  Evolution of nodule stiffness might predict response to local ablative therapy: A series of patients with hepatocellular carcinoma.

Authors:  Michael Praktiknjo; Viktoria Krabbe; Alessandra Pohlmann; Matthias Sampels; Christian Jansen; Carsten Meyer; Christian P Strassburg; Jonel Trebicka; Maria A Gonzalez Carmona
Journal:  PLoS One       Date:  2018-02-14       Impact factor: 3.240

3.  Piezoelectric needle sensor reveals mechanical heterogeneity in human thyroid tissue lesions.

Authors:  Shivani Sharma; Renato Aguilera; JianYu Rao; James K Gimzewski
Journal:  Sci Rep       Date:  2019-06-26       Impact factor: 4.379

4.  Distinction between benign and malignant soft tissue tumors based on an ultrasonographic evaluation of vascularity and elasticity.

Authors:  Shusa Ohshika; Tatsuro Saruga; Tetsuya Ogawa; Hiroya Ono; Yasuyuki Ishibashi
Journal:  Oncol Lett       Date:  2021-02-10       Impact factor: 2.967

5.  Multi-parameter ultrasound based on the logistic regression model in the differential diagnosis of hepatocellular adenoma and focal nodular hyperplasia.

Authors:  Meng Wu; Ru-Hai Zhou; Feng Xu; Xian-Peng Li; Ping Zhao; Rui Yuan; Yu-Peng Lan; Wei-Xia Zhou
Journal:  World J Gastrointest Oncol       Date:  2019-12-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.