Sarah Anderson1, Rwth Stuckey2, Diana Poole3, Jodi Oakman1.
Abstract
Prosthetists and Orthotists (P&O) are exposed to physical hazards within the workshop environment. Concern regarding these exposures has been expressed by P&Os; however, little research has been undertaken. Exposures to noise and volatile organic compounds in amounts larger than statutorily allowed can have adverse short and long term consequences on people's health. To identify and quantify hazardous noise and chemical exposures in a typical P&O workplace. Noise and volatile organic compound testing was undertaken in 2011 and 2013. Modifications to the workshop occurred between these testing times and the impact of these changes examined. The levels of volatile organic compounds was very low in all areas in 2011 and 2013. Noise levels were high and staff require the use of PPE to prevent exposure beyond levels prescribed in the Australian Standards.Entities:
Keywords: Exposure; Health care; Noise; Volatile organic compounds; Work environments
Mesh:
Substances:
Year: 2017 PMID: 28179609 PMCID: PMC5462644 DOI: 10.2486/indhealth.2016-0089
Source DB: PubMed Journal: Ind Health ISSN: 0019-8366 Impact factor: 2.179
Fig. 1. Workshop layout.
Acceptable exposure limits for the assessed VOCs23)
| Contaminant | TWA Exposure Standards |
|---|---|
| Isopropyl Alcohol | 400 ppm |
| Acetone | 500 ppm |
| Ethyly Alcohol | 1,000 ppm |
| Toluene | 50 ppm |
| Xylenes | 80 ppm |
| MEK | 150 ppm |
| Methyl Methacrylate | 50 ppm |
| Pentanes | 600 ppm |
2011 Noise levels
| Area/Operation | LAeq 1 min | period before eight h | Points where/when measurements taken |
|---|---|---|---|
| Grinder | 88 | 4:00 | During grinding of orthotic. |
| Grinder | 84 | 10:00 | Whilst no grinding was being undertaken but extraction was on. |
| Grinder | 88 | 4:00 | Grinding orthotic |
| Right hand extraction hood | 93 | 1:16 | 30 cm from hood. Both left and right hood slide gate dampers open. |
| Right hand extraction hood | 89 | 3:12 | 30 cm from hood. Both left side gate damper closed and right slide damper open. |
| Left hand extraction hood | 93 | 1:16 | 30 cm from hood. Both left and right hood slide gate dampers open |
| Left hand extraction hood | 96 | 0:38 | 30 cm from hood. Both left side gate damper closed and right slide damper open |
*without hearing protection
2013 Noise levels
| Area/Operation | LAeq 1 min | period before eight h | Points where/when measurements taken |
|---|---|---|---|
| Grinder | 95 | 0:47 | Fan speed 100% with all other outlets blocked off |
| Grinder | 92 | 1:35 | Fan speed 100% with one other outlet open |
| Grinder | 89 | 3:11 | Fan speed 100% with all other outlet open |
| Grinder | 83 | >12 | Fan speed 60% and all other outlets closed |
| Chipping plaster leg mould with air chisel to | 103 | 0:07 | At staff member’s ear |
| Chipping plaster leg mould with air chisel to | 82 | >12 | Outside Grinding Room during chisel use. |
| Laminating Room | 74 | >12 | |
| Gluing Bench | 78 | >12 | Rear extraction only on. |
| Gluing Bench | 75 | >12 | Both rear extraction and flexible arm extraction on. |
*without hearing protection
2011 Volatile Organic Compounds assessment results
| Operator | Process | Total time | TWA (ppm) | TWA Exposure Standards |
|---|---|---|---|---|
| P&O technician | • Sealing orthotic casts using methylated spirit | 474 | Methyl Methacrylate=ND | 50 ppm |
| Orthotist | • Plaster Work | 471 | Methyl Methacrylate=ND | 50 ppm |
| Prosthetist | • Cleaning using Foss Solvent | 493 | Methyl Methacrylate=ND | 50 ppm |
| Orthotist | • Making toe prop using Orthoform 2-part silicone | 473 | Methyl Methacrylate=ND | 50 ppm |
ND=Not Detected
No other specific VOC’s were detected in any of the samples
2013 Volatile Organic Compound results
| Operator | Process | Total time | TWA (ppm) | TWA Exposure Standards (maximum allowed) |
|---|---|---|---|---|
| Technician | Sealing orthotic casts using methylated spirits | 277 | Pentanes=16.25 ppm | 600 ppm |
| Prosthetist | Plaster Work | 387 | Methyl Methacrylate=ND | 50 ppm |
| Prosthetist | Plaster Work | 396 | Methyl Methacrylate=ND | 50 ppm |
ND=Not Detected
No other specific VOC’s were detected in any of the samples