Literature DB >> 28179167

MRI and MRS of the human brain at magnetic fields of 14T to 20T: Technical feasibility, safety, and neuroscience horizons.

Thomas F Budinger1, Mark D Bird2.   

Abstract

The three goals of this paper are: 1) to evaluate the improvements in technology for increasing magnetic flux density (magnetic field) to 14T in the next few years and eventually to 20T; 2) to highlight neuroscience opportunities enabled by these advances; and, 3) to evaluate the physiological and biophysical effects associated with MRI at very high performance levels. Substantial recent advances in magnet technology including superconductor developments enable neuroscience goals that are not obtainable at contemporary magnetic fields. Ten areas of brain neuroscience include potential improvements in resolution for functional MRI(BOLD), diffusion weighted MRI, tractography, susceptibility weighted MR, neuronal architecture patterns related to human behavior, proton spectroscopy of small brain biochemicals, chemical exchange saturation transfer (CEST), dynamic contrast enhanced MRI, brain energy metabolism using 13C, 17O, and 31P; and brain electrolyte physiology using 23Na, 35Cl, and 39K. Physiological phenomena and safety aspects include: absorbed RF power, acoustic sound pressure levels, induced electric fields, Lorentz forces, magnetohydrodynamic forces, and biophysical phenomena in cells and tissues. Where feasible, effects are quantified for magnetic fields beyond 7T with the conclusion that there are no foreseen barriers either in the technical or human safety aspects of brain MRI and MRS at fields up to 20T. This conclusion is conditioned on results of recommended experiments to verify the predicted level of physiological effects beyond 9.4T. This technology is predicted to enable quantification of biochemical components of the functioning brain not detectable heretofore.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28179167     DOI: 10.1016/j.neuroimage.2017.01.067

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  16 in total

Review 1.  Human brain atlasing: past, present and future.

Authors:  Wieslaw L Nowinski
Journal:  Neuroradiol J       Date:  2017-11-03

2.  Nonparametric 5D D-R2 distribution imaging with single-shot EPI at 21.1 T: Initial results for in vivo rat brain.

Authors:  Jens T Rosenberg; Samuel C Grant; Daniel Topgaard
Journal:  J Magn Reson       Date:  2022-06-15       Impact factor: 2.734

Review 3.  Functional brain imaging in neuropsychology over the past 25 years.

Authors:  David R Roalf; Ruben C Gur
Journal:  Neuropsychology       Date:  2017-11       Impact factor: 3.295

Review 4.  Probing the brain with molecular fMRI.

Authors:  Souparno Ghosh; Peter Harvey; Jacob C Simon; Alan Jasanoff
Journal:  Curr Opin Neurobiol       Date:  2018-04-09       Impact factor: 6.627

Review 5.  Imaging faster neural dynamics with fast fMRI: A need for updated models of the hemodynamic response.

Authors:  Jonathan R Polimeni; Laura D Lewis
Journal:  Prog Neurobiol       Date:  2021-09-12       Impact factor: 11.685

6.  An in vivo multimodal feasibility study in a rat brain tumour model using flexible multinuclear MR and PET systems.

Authors:  Chang-Hoon Choi; Carina Stegmayr; Aliaksandra Shymanskaya; Wieland A Worthoff; Nuno A da Silva; Jörg Felder; Karl-Josef Langen; N Jon Shah
Journal:  EJNMMI Phys       Date:  2020-07-29

7.  Feasibility of functional magnetic resonance imaging of ocular dominance and orientation preference in primary visual cortex.

Authors:  Marilia Menezes de Oliveira; James C Pang; Peter A Robinson; Xiaochen Liu; Mark M Schira
Journal:  PLoS Comput Biol       Date:  2019-11-04       Impact factor: 4.475

Review 8.  Occupational exposure to electromagnetic fields from medical sources.

Authors:  Rianne Stam; Sachiko Yamaguchi-Sekino
Journal:  Ind Health       Date:  2017-11-03       Impact factor: 2.179

9.  Comparison Of Surgical Outcomes Between Excisional Goniotomy Using The Kahook Dual Blade And iStent Trabecular Micro-Bypass Stent In Combination With Phacoemulsification.

Authors:  Dayeong Lee; Joshua King; Samuel Thomsen; Matthew Hirabayashi; Jella An
Journal:  Clin Ophthalmol       Date:  2019-10-25

Review 10.  Neuroimaging Biomarkers for Predicting Treatment Response and Recurrence of Major Depressive Disorder.

Authors:  Seung-Gul Kang; Seo-Eun Cho
Journal:  Int J Mol Sci       Date:  2020-03-20       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.