Total cervical tracheal stenosis: treatment by laser, dilation, and stenting.

S M Shapshay1, J F Beamis, J F Dumon.   

Abstract

Twelve patients with total cervical tracheal stenosis were treated by endoscopic laser excision (neodymium:yttrium aluminum garnet or carbon dioxide laser), bronchoscopic dilation, and prolonged stenting with a silicone T-tube. All patients had previous traumatic or prolonged endotracheal intubation requiring a tracheotomy and presented with aphonia as the major complaint. Multiple laser and dilation treatments were necessary in ten patients. Average duration of T-tube placement was 6 months. Excellent results (decannulation and good voice) were achieved in eight patients with a follow-up of 9 months to 6 years. Persistent granulation tissue and some degree of fibrosis were the most common complications (eight of 12 patients). Two patients died of medical complications. A high success rate with this endoscopic technique justifies this approach as our initial therapy, with open surgical techniques reserved for failure.

Entities:  

Mesh:

Year:  1989        PMID: 2817681     DOI: 10.1177/000348948909801110

Source DB:  PubMed          Journal:  Ann Otol Rhinol Laryngol        ISSN: 0003-4894            Impact factor:   1.547


  3 in total

1.  Chronic subglottic and tracheal stenosis: endoscopic management vs. surgical reconstruction.

Authors:  Mohammed Mandour; Marc Remacle; Paul Van de Heyning; Samy Elwany; Ahmed Tantawy; Alaa Gaafar
Journal:  Eur Arch Otorhinolaryngol       Date:  2003-03-26       Impact factor: 2.503

2.  Management of laryngotracheal stenosis using dilatation and stenting.

Authors:  S Ramdev; P Ghosh; S Mukhopadhyaya
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2003-04

3.  A Novel Insertion Technique for the Extra-Long Montgomery T-Tube in Patients with a Large Mediastinal Tumor.

Authors:  Tatsuya Kato; Aki Fujiwara-Kuroda; Nobuyuki Shiina; Masato Aragaki; Hideki Ujiie; Yasuhiro Hida; Kichizo Kaga
Journal:  Ann Thorac Cardiovasc Surg       Date:  2020-08-01       Impact factor: 1.520