Efficacy of Flow Monitoring During ECMO.

Aditya Badheka1, Sara E Stucker, Joseph W Turek, Madhavan L Raghavan.   

Abstract

The hypothesis that blood flow monitoring could serve as an effective early indicator of distal obstruction during extracorporeal membrane oxygenation (ECMO) was tested under controlled experimental conditions. The ECMO circuit typically includes (or could be easily modified to include) a shunt that bifurcates from the main line returning a small amount of blood to the pump with access points for drug infusions. Distal circuit obstructions in the oxygenator and beyond will result in an increased diversion of flow from the distal line to the shunt. Thus, elevations in flow through the shunt can serve as a marker for distal circuit obstruction. An ECMO training circuit was adapted with a resistance chamber that simulates controlled and varying levels of distal obstructions. Experiments were conducted under pediatric and adult pump target flow rates simulating different levels of distal obstructions while documenting the shunt flow and pressure drop across the obstruction. There was measurable and statistically significant elevation in the shunt flow at all flow rates because of different levels of obstruction from baseline values and hence consistent with the hypothesis that shunt flow can serve as an indicator of distal obstruction in the ECMO circuit. Flow monitoring is over the tube, hands free, continuous, and easy to implement. Therefore, it has the potential to serve as an early nonspecific indicator of elevated distal resistance in the ECMO circuit, which can then trigger other measurements (such as pressure drop across the oxygenator) for a more specific assessment of the source for distal resistance.

Entities:  

Mesh:

Year:  2017        PMID: 28169848      PMCID: PMC5736305          DOI: 10.1097/MAT.0000000000000538

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  Evolution of the extracorporeal life support circuitry.

Authors:  David Palanzo; Feng Qiu; Larry Baer; J Brian Clark; John L Myers; Akif Undar
Journal:  Artif Organs       Date:  2010-11       Impact factor: 3.094

2.  Pediatric ECMO outcomes: comparison of centrifugal versus roller blood pumps using propensity score matching.

Authors:  Cindy S Barrett; James J Jaggers; E Francis Cook; Dionne A Graham; Vasmi V Yarlagadda; Sarah A Teele; Christopher S Almond; Susan L Bratton; John D Seeger; Heidi J Dalton; Peter T Rycus; Peter C Laussen; Ravi R Thiagarajan
Journal:  ASAIO J       Date:  2013 Mar-Apr       Impact factor: 2.872

3.  Laboratory evaluation of a double lumen catheter for venovenous neonatal ECMO.

Authors:  T Otsu; S I Merz; K A Hultquist; R J Attorri; H L Anderson; D E Scheffler; A Ahmad; R H Bartlett
Journal:  ASAIO Trans       Date:  1989 Jul-Sep

4.  Outcomes of neonates undergoing extracorporeal membrane oxygenation support using centrifugal versus roller blood pumps.

Authors:  Cindy S Barrett; James J Jaggers; E Francis Cook; Dionne A Graham; Satish K Rajagopal; Christopher S Almond; John D Seeger; Peter T Rycus; Ravi R Thiagarajan
Journal:  Ann Thorac Surg       Date:  2012-08-24       Impact factor: 4.330

5.  An ex vivo evaluation of blood coagulation and thromboresistance of two extracorporeal circuit coatings with reduced and full heparin dose.

Authors:  Leylah Teligui; Emilie Dalmayrac; Guillaume Mabilleau; Laurent Macchi; Alban Godon; Jean-Jacques Corbeau; Anne-Sophie Denommé; Emmanuelle Bouquet; Christa Boer; Christophe Baufreton
Journal:  Interact Cardiovasc Thorac Surg       Date:  2014-03-14

6.  Hemorrhagic complications in pediatric cardiac patients on extracorporeal membrane oxygenation: an analysis of the Extracorporeal Life Support Organization Registry.

Authors:  David K Werho; Sara K Pasquali; Sunkyung Yu; Janet Donohue; Gail M Annich; Ravi R Thiagarajan; Jennifer C Hirsch-Romano; Michael G Gaies
Journal:  Pediatr Crit Care Med       Date:  2015-03       Impact factor: 3.624

  6 in total
  3 in total

1.  A Novel Mock Circuit to Test Full-Flow Extracorporeal Membrane Oxygenation.

Authors:  Stefan Caspari; Leonie S Schwärzel; Anna M Jungmann; Nicole Schmoll; Frederik Seiler; Ralf M Muellenbach; Marcin Krawczyk; Quoc Thai Dinh; Robert Bals; Philipp M Lepper; Albert J Omlor
Journal:  Membranes (Basel)       Date:  2022-04-30

2.  Hemodynamic evaluation and in vitro hemolysis evaluation of a novel centrifugal pump for extracorporeal membrane oxygenation.

Authors:  Minrui Fu; Gang Liu; Weining Wang; Bin Gao; Bingyang Ji; Yu Chang; Youjun Liu
Journal:  Ann Transl Med       Date:  2021-04

3.  Predictors of circuit health in neonatal patients receiving extracorporeal membrane oxygenation (ECMO).

Authors:  Rita G Hazboun; Nada Darwish; Gianna Rotyliano-Sykes; Nayef Chahin; Jie Xu; John Miller; Christos Calaritis; Leroy Thacker; Russell Moores; Karen D Hendricks-Muñoz
Journal:  Sci Rep       Date:  2022-01-24       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.