Tissue oxygen saturation levels from fetus to neonate.

Mari Mukai1, Toshiyuki Uchida1, Hiroaki Itoh1, Hikaru Suzuki2, Masatsugu Niwayama3,4, Naohiro Kanayama1.   

Abstract

AIM: Oxygen saturation during the term of delivery to the first cry, when fetal circulation dynamically changes, has not yet been examined. The aim of this study was therefore to determine whether the continuous measurement of regional tissue oxygen saturation (rSO2 ) from crowning until 5 min after delivery is possible using fetal tissue oximetry with a sensor attached to the examiner's finger.
METHODS: Oxygen saturation levels in fetal cranial tissue between the second stage of delivery to crowning and up to 5 min after delivery were measured using fetal tissue oximetry with a sensor attached to the examiner's finger. Thirty-five deliveries were examined, and oxygen saturation was measured in seven infants from delivery of the head until 5 min after birth. Umbilical cord blood gas was measured in all cases. This clinical test was performed under the permission of the Ethics Committee of Hamamatsu University School of Medicine.
RESULTS: Average tissue oxygen saturation in the second stage of delivery and at 5 min after delivery were 50.3 ± 16.3% and 56.8 ± 8.46%, respectively. In cases of continuous measurement, average rSO2 for crowning, immediately after delivery, and the first cry was 32.7 ± 9.5%, 30.0 ± 6.6%, and 31.6 ± 5.5%, respectively.
CONCLUSION: We herein successfully measured oxygen saturation levels in fetal cranial tissue during crowning, delivery of the head, the first cry, and 5 min after delivery using fetal tissue oximetry with a sensor attached to the examiner's finger.
© 2017 Japan Society of Obstetrics and Gynecology.

Entities:  

Keywords:  fetal tissue oximetry; fetal tissue oxygen saturation; near-infrared spectroscopy; newborn; parturition

Mesh:

Year:  2017        PMID: 28168777     DOI: 10.1111/jog.13295

Source DB:  PubMed          Journal:  J Obstet Gynaecol Res        ISSN: 1341-8076            Impact factor:   1.730


  4 in total

1.  A Pilot Study Investigating the Use of Regional Oxygen Saturation as a Predictor of Ischemic Wound Healing Outcome after Endovascular Treatment in Patients with Chronic Limb-Threatening Ischemia.

Authors:  Takafumi Kayama; Masaki Sano; Kazunori Inuzuka; Kazuto Katahashi; Tatsuro Yata; Yuta Yamanaka; Ena Naruse; Naoto Yamamoto; Hiroya Takeuchi; Naoki Unno
Journal:  Ann Vasc Dis       Date:  2021-03-25

2.  Term Newborns with relatively low Tissue Oxygen Saturation Levels soon after Birth are predisposed to Neonatal Respiratory Disorders in Low-risk, Elective Cesarean Sections.

Authors:  Kenta Kawai; Toshiyuki Uchida; Mari Mukai; Masako Matsumoto; Toshiya Itoh; Tomoaki Oda; Yoshimasa Horikoshi; Kazunao Suzuki; Yukiko Kohmura-Kobayashi; Naomi Furuta-Isomura; Chizuko Yaguchi; Masatsugu Niwayama; Hiroaki Itoh; Naohiro Kanayama
Journal:  Int J Med Sci       Date:  2021-03-30       Impact factor: 3.738

Review 3.  Optimizing oxygen therapy for preterm infants at birth: Are we there yet?

Authors:  Vishal Kapadia; Ju Lee Oei
Journal:  Semin Fetal Neonatal Med       Date:  2020-01-16       Impact factor: 3.926

4.  Association of objectively measured physical fitness during pregnancy with maternal and neonatal outcomes. The GESTAFIT Project.

Authors:  Laura Baena-García; Irene Coll-Risco; Olga Ocón-Hernández; Lidia Romero-Gallardo; Pedro Acosta-Manzano; Linda May; Virginia A Aparicio
Journal:  PLoS One       Date:  2020-02-18       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.