Literature DB >> 28168640

3D Computer graphical anatomy study of the femur: a basis for a new nail design.

Beat Schmutz1, Stanley Kmiec2, Martin E Wullschleger3, Martin Altmann4, Michael Schuetz5,6.   

Abstract

BACKGROUND: Current intramedullary nails with a radius of curvature (ROC) of 1500-2000 mm sometimes cause distal anterior cortical encroachment. Furthermore, clinical data indicate that the proximal nail end is too long for some Asian patients. The objective of our study was to develop a comprehensive 3D measurement protocol that measures both the anatomy of the canal and the proximal region. The protocol was used to obtain measurements from Caucasian and Asian (Japanese and Thai) specimens.
MATERIALS AND METHODS: A total of 90 3D bone models representative of hip fracture patients were reconstructed from CT data. RapidForm 2006 was used to generate the reference geometries required for determining radius and angulation of shaft antecurvature as well as measurements of the proximal anatomy. Multiple linear regression analyses were used to determine the relative contribution of height, age, ethnicity, gender, and body side on the total variance.
RESULTS: The mean ROC in the natural 3D antecurvature plane was 885 mm overall, 974 mm in Caucasians and 787 mm in Asians. Height, age, ethnicity, gender, and body side significantly predicted ROC (R = 0.53, p = 0.000). The mean values of anteversion measurements for Asians (Japanese: 22.1°; Thai: 22.7°) were significantly larger than those of the Caucasians (14.5°; p = 0.001). There was virtually no difference (p = 0.186) between the measurements pertaining to the length of the proximal nail end between Caucasian and Asian samples. There was no significant difference between the mean neck-to-shaft angles (Caucasian: 126°; Japanese: 128.2°; Thai: 125.7°; p = 0.198 for Asians vs Caucasians).
CONCLUSIONS: The developed comprehensive anatomical 3D measurement protocol could serve as standardised approach for anthropometric studies in the future. Our data suggest that the ROC of current nail designs should be reduced from between 1500 and 2000 to 1000 mm to achieve an improved fit for the investigated population.

Entities:  

Keywords:  3D models; Anatomy; Femur; Fracture fixation; Intramedullary nails

Mesh:

Year:  2017        PMID: 28168640     DOI: 10.1007/s00402-016-2621-7

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  A Simple Method to Improve Detection of Femoral Nail Abutment in the Distal Femur: A Computer Modeling Study.

Authors:  Harminder Sarai; Beat Schmutz; Michael Schuetz
Journal:  Clin Orthop Relat Res       Date:  2022-03-28       Impact factor: 4.755

2.  A novel radiological classification system of the distal femur.

Authors:  Mustafa Citak; Ali Levent; Eduardo M Suero; Kristof Rademacher; Sophia-Marlene Busch; Thorsten Gehrke
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-27       Impact factor: 3.067

3.  An innovative method for measuring the femoral arch.

Authors:  Dong Ren; Tianci Wang; Ming Li; Yueju Liu; Yajie Huang; Pengcheng Wang
Journal:  Medicine (Baltimore)       Date:  2019-04       Impact factor: 1.817

4.  A comparison between Asians and Caucasians in the dimensions of the femoral isthmus based on a 3D-CT analysis of 1189 adult femurs.

Authors:  Darius M Thiesen; Dimitris Ntalos; Alexander Korthaus; Andreas Petersik; Karl-Heinz Frosch; Maximilian J Hartel
Journal:  Eur J Trauma Emerg Surg       Date:  2021-07-28       Impact factor: 2.374

5.  Femoral antecurvation-A 3D CT Analysis of 1232 adult femurs.

Authors:  Darius M Thiesen; Felix Prange; Josephine Berger-Groch; Dimitris Ntalos; Andreas Petersik; Bernhard Hofstätter; Johannes M Rueger; Till O Klatte; Maximilian J Hartel
Journal:  PLoS One       Date:  2018-10-09       Impact factor: 3.240

6.  Notching is less, if femoral component sagittal positioning is planned perpendicular to distal femur anterior cortex axis, in navigated TKA.

Authors:  Raj Kanna; Chandramohan Ravichandran; Gautam M Shetty
Journal:  Knee Surg Relat Res       Date:  2021-12-24
  6 in total